Temperature-controlled and constant-power radio-frequency ablation: what affects lesion growth?

Abstract: Radio-frequency (RF) catheter ablation is the primary interventional therapy for the treatment of many cardiac tachyarrhythmias. Three-dimensional finite element analysis of constant-power (CPRFA) and temperature-controlled RF ablation (TCRFA) of the endocardium is performed. The objectives are to study: 1) the lesion growth with time and 2) the effect of ground electrode location on lesion dimensions and ablation efficiency. The results indicate that: a) for TCRFA: i) lesion growth was fastest during the firs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
77
0

Year Published

2001
2001
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 72 publications
(77 citation statements)
references
References 19 publications
0
77
0
Order By: Relevance
“…Several studies have been conducted to describe lesion growth for radiofrequency ablation devices [2,[9][10][11][12]21,24,[29][30][34][35]. In the majority of these cases, markers such as temperature isotherms and thermal dosing are used as the primary measure for lesion size.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies have been conducted to describe lesion growth for radiofrequency ablation devices [2,[9][10][11][12]21,24,[29][30][34][35]. In the majority of these cases, markers such as temperature isotherms and thermal dosing are used as the primary measure for lesion size.…”
Section: Discussionmentioning
confidence: 99%
“…The situation has been simplified by ignoring Q p and Q m as they are negligible for RF heating [19].…”
Section: A Description Of the Theoretical Modelmentioning
confidence: 99%
“…However, to our knowledge, the majority of the numerical models of RF heating using an active electrode include only a limited fragment of biological tissue and active electrode [17,19,22,26,[36][37][38][39]. Computer simulations have been carried out in all these cases in order to determine the appropriate model dimensions.…”
Section: H Electrical Conductivity Dispersionmentioning
confidence: 99%
See 1 more Smart Citation
“…Certain factors are known to have an impact on lesion size, e.g. tissue characteristics [4], electrode-tissue contact characteristics [5][6][7][8][9][10], electrode size [10], arrangement [11][12][13][14] and position [15,16] of the temperature sensor embedded in the electrode. Conversely, it is also known that varying these characteristics would affect the performance of the temperature control system.…”
Section: Introductionmentioning
confidence: 99%