2015
DOI: 10.1016/j.chroma.2015.05.071
|View full text |Cite
|
Sign up to set email alerts
|

Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from pre-column dispersion and volume overload when used alone or with solvent-based focusing

Abstract: On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 24 publications
(26 citation statements)
references
References 26 publications
(29 reference statements)
0
26
0
Order By: Relevance
“…58 Briefly, timed injections were made using an external 6-port Cheminert injection valve (C72x-669D, VICI Valco, Houston, TX) fitted with a 75 µm × 75 cm nanoViper capillary (Thermo) loop. Samples were loaded into the sample loop using the loading pump and autosampler of the NSC-3500 system.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…58 Briefly, timed injections were made using an external 6-port Cheminert injection valve (C72x-669D, VICI Valco, Houston, TX) fitted with a 75 µm × 75 cm nanoViper capillary (Thermo) loop. Samples were loaded into the sample loop using the loading pump and autosampler of the NSC-3500 system.…”
Section: Methodsmentioning
confidence: 99%
“…57,58 With TASF, the head of the column is cooled to subambient temperatures during injection. This results in focusing of solutes into narrow bands at the head of the column.…”
mentioning
confidence: 99%
“…1. Hardware was similar to that used for single-stage TASF [53, 55]. In this instrument we constructed an array of three independently controlled 1.0 × 1.0 cm, 10.9 W thermoelectric elements (Peltiers, TECs) from Custom Thermoelectric (04801-9330-34RB, Bishopville, MD).…”
Section: Instrumentation and Chromatographic Conditionsmentioning
confidence: 99%
“…Fused silica capillary columns were packed in-house using a previously described procedure [28, 53, 55]. Briefly, Waters Acquity BEH C18, 1.7 µm d p , particles were packed into 150 µm diameter fused silica capillaries from Polymicro Technologies (Phoenix, AZ).…”
Section: Instrumentation and Chromatographic Conditionsmentioning
confidence: 99%
See 1 more Smart Citation