2003
DOI: 10.1007/s00540-003-0174-8
|View full text |Cite
|
Sign up to set email alerts
|

Temperature and humidity of the Dr�ger Cato anesthetic machine circuit

Abstract: The present study indicates that the Dräger Cato machine was more effective in warming and humidifying respiratory gas than the Aestiva/5, and that Aestiva/5 without HME does not reach the optimal temperature and humidity ranges, even if minimal flow anesthesia (0.51 x min(-1)) is performed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
0
3

Year Published

2014
2014
2017
2017

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(16 citation statements)
references
References 12 publications
1
12
0
3
Order By: Relevance
“…Gases were assessed using a clinical, main-stream capacitive thermohygrometer (Moiscope, Siynet, Tokyo, Japan; response time, 3 s within the range of 40 to 100%; accuracy, ±0.5°C for temperature and ±3.5% for relative humidity) [12, 13] placed between the distal end of the inspiratory circuit and the Y-piece (“Y-piece” temperature and humidity) (Figure 1). Although this thermohygrometer is designed for continuous monitoring, we took out the sensor from the circuit to dry it up when studies persisted longer than 10 minutes, or when condensation was observed within the circuit adjacent to the sensor.…”
Section: Methodsmentioning
confidence: 99%
“…Gases were assessed using a clinical, main-stream capacitive thermohygrometer (Moiscope, Siynet, Tokyo, Japan; response time, 3 s within the range of 40 to 100%; accuracy, ±0.5°C for temperature and ±3.5% for relative humidity) [12, 13] placed between the distal end of the inspiratory circuit and the Y-piece (“Y-piece” temperature and humidity) (Figure 1). Although this thermohygrometer is designed for continuous monitoring, we took out the sensor from the circuit to dry it up when studies persisted longer than 10 minutes, or when condensation was observed within the circuit adjacent to the sensor.…”
Section: Methodsmentioning
confidence: 99%
“…The Cato (Dräger) machine was more effective in warming and humidifying the respiratory gas than the Aestiva machine. [9] The Primus anesthesia workstation also had a significant effect on the temperature, relative humidity, and absolute humidity of the respiratory gas with low FGF. [10] …”
Section: Introductionmentioning
confidence: 99%
“…O nível ótimo de condicionamento artificial do gás inalado ainda não foi determinado, porém há concordância na literatura em se instituir limites de aquecimento e umidificação desses gases (Tsuda et al, 1977;Forbes et al, 1974;Wada et al, 2003). Estudos prévios estabeleceram uma variação da UA inspirada durante ventilação mecânica entre 23 a 33 mg.L -1 e Temperatura entre 28 a 32°C (Tsuda et al, 1977;Forbes et al, 1974 (Williams et al, 1996).…”
Section: Análise Longitudinal Para Os Parâmetros De Tmc Tt E Acunclassified
“…Por outro lado, o equipamento Dräger possui propriedades de umidificação especiais no sistema respiratório. Este aparelho foi projetado para que o fluxo de gases frescos passe três vezes pela cal sodada, antes de ser enviado para o paciente, além de haver uma placa de aquecimento do gás expirado, para evitar condensação de água no sistema (Wada et al, 2003;Kleemann et al, 1994 Os efeitos da intubação endotraqueal e da anestesia geral no muco respiratório são controversos. Na literatura há estudos que demonstram uma diminuição dose-dependente da velocidade de transporte traqueal em pacientes que receberam anestesia inalatória e com barbitúricos (Ledowski et al, 2006;Cervin et al, 1995, Pizov et al, 1992.…”
Section: Análise Longitudinal Para Os Parâmetros De Tmc Tt E Acunclassified
See 1 more Smart Citation