2014
DOI: 10.1093/eurheartj/ehu330
|View full text |Cite
|
Sign up to set email alerts
|

Telemedicine-guided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants

Abstract: Telemedicine-guided very low-dose INR self-control is comparable with low-dose INR in thrombotic risk, and is superior in bleeding risk. Weekly testing is sufficient. Given the small number of MVR and DVR patients, results are only valid for AVR patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
38
0
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(41 citation statements)
references
References 16 publications
0
38
0
3
Order By: Relevance
“…171 Recent randomized trials supported lower target INRs for aortic prostheses. [186][187][188] However, limited statistical power, certain methodological concerns and the restriction to certain prostheses and/or to the use of INR selfmanagement led the Task Force not to change recommendations for target INR. We recommend a median INR value rather than a range to avoid considering extreme values in the target range as a valid target INR. High variability of the INR is a strong independent predictor of reduced survival after valve replacement.…”
Section: Target International Normalized Ratiomentioning
confidence: 99%
“…171 Recent randomized trials supported lower target INRs for aortic prostheses. [186][187][188] However, limited statistical power, certain methodological concerns and the restriction to certain prostheses and/or to the use of INR selfmanagement led the Task Force not to change recommendations for target INR. We recommend a median INR value rather than a range to avoid considering extreme values in the target range as a valid target INR. High variability of the INR is a strong independent predictor of reduced survival after valve replacement.…”
Section: Target International Normalized Ratiomentioning
confidence: 99%
“…Algunos estudios aleatorizados recientes respaldan el uso de objetivos de INR más bajos en el caso de las prótesis aórticas [186][187][188] . Sin embargo, debido a su escasa potencia estadística, algunos problemas metodológicos y la restricción a ciertas prótesis o el control del INR por el propio paciente, este Grupo de Trabajo no ha cambiado las recomendaciones sobre el objetivo de INR.…”
Section: Objetivo De Cociente Internacional Normalizado (Inr)unclassified
“…The final model for predicting poor anticoagulation control included intensity of target range, interval of measurements, type of management and sex, with an area under the ROC curve of 0Á65 (95% CI 0Á64, 0Á66; see Fig 2). Several sensitivity analyses were conducted: (i) using (Koertke et al, 2007(Koertke et al, , 2015. Several sensitivity analyses were conducted: (i) using (Koertke et al, 2007(Koertke et al, , 2015.…”
Section: Prediction Modelmentioning
confidence: 99%