2017
DOI: 10.1515/sgem-2017-0010
|View full text |Cite
|
Sign up to set email alerts
|

Technical Note. The Concept of a Computer System for Interpretation of Tight Rocks Using X-Ray Computed Tomography Results

Abstract: Abstract:The article presents the concept of a computer system for interpreting unconventional oil and gas deposits with the use of X-ray computed tomography results. The functional principles of the solution proposed are presented in the article. The main goal is to design a product which is a complex and useful tool in a form of a specialist computer software for qualitative and quantitative interpretation of images obtained from X-ray computed tomography. It is devoted to the issues of prospecting and ident… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 19 publications
0
3
0
1
Order By: Relevance
“…Using binarization (threshold method), the pore space was extracted from the image and filtrated against the noise. The second stage was connected with the qualitative and quantitative interpretation of the pore space using poROSE software (poROus materials examination SoftwarE, AGH University of Science and Technology, Kraków, Poland) [29,30]. The scheme of the CT analysis is presented in Figure 1.…”
Section: Computed X-ray Tomography (Ct)mentioning
confidence: 99%
“…Using binarization (threshold method), the pore space was extracted from the image and filtrated against the noise. The second stage was connected with the qualitative and quantitative interpretation of the pore space using poROSE software (poROus materials examination SoftwarE, AGH University of Science and Technology, Kraków, Poland) [29,30]. The scheme of the CT analysis is presented in Figure 1.…”
Section: Computed X-ray Tomography (Ct)mentioning
confidence: 99%
“…Zastosowano detektor firmy Hamamatsu HAM C 7942CA-02, który pozwolił uzyskać rozdzielczość obrazu 800 nm. Obrazy tomograficzne były interpretowane jakościowo i ilościowo przy wykorzystaniu programu poROSE (po-ROus materials examination SoftwarE) [3,7]. Program poROSE jest wynikiem prac badawczych prowadzonych wspólnie przez ośrodki naukowe i przemysłowe na materiałach porowatych.…”
Section: Materiał I Metodaunclassified
“…shale gas, tight sandstones, and tight carbonates). The geometrical model was reproduced using results of computer tomography technique (micro-CT) and developed tools and algorithms (poROSE software) for the analysis of the images of porous materials (Habrat et al , 2017; Krakowska et al , 2018b).…”
Section: Introductionmentioning
confidence: 99%