Technical Note: DIRART – A software suite for deformable image registration and adaptive radiotherapy research

Abstract: By exchanging data with treatment planning systems via DICOM-RT files and CERR, and by bringing image registration algorithms closer to radiotherapy applications, DIRART is potentially a convenient and flexible platform that may facilitate ART and DIR research. 0 2011 Ameri-

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
42
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 83 publications
(43 citation statements)
references
References 59 publications
0
42
0
Order By: Relevance
“…the DIRART [17], were tested. These DIR algorithms includes four optical flow based methods: the Original Horn and Schunck (HSO), the Horn and Schunck with Issam's non-linear smoothness (HS_INLS), the combined Horn-Schunck and Lucas-Kanade (HSLK) and the iterative optical flow (IOF); one level-set based method: the original level set motion (OLSM); one demons based method: the double force demons (DFD), and one iterative method: the free form deformation (FFD).…”
Section: Dir Algorithmsmentioning
confidence: 99%
“…the DIRART [17], were tested. These DIR algorithms includes four optical flow based methods: the Original Horn and Schunck (HSO), the Horn and Schunck with Issam's non-linear smoothness (HS_INLS), the combined Horn-Schunck and Lucas-Kanade (HSLK) and the iterative optical flow (IOF); one level-set based method: the original level set motion (OLSM); one demons based method: the double force demons (DFD), and one iterative method: the free form deformation (FFD).…”
Section: Dir Algorithmsmentioning
confidence: 99%
“…GTVs were contoured by veterinarians using pretreatment CT images. For each patient, pretreatment and midtreatment CT images were deformably registered by use of the optical flow algorithm (23), and the resulting transformations were applied to their respective PET data. This allowed for voxel-based comparisons of pretreatment and midtreatment tracer distributions.…”
Section: Methodsmentioning
confidence: 99%
“…Selection of the algorithm employed for this study was justified based on our previous study, 25 , 26 as well as those of other groups 15 , 17 who have similarly used it in the context of lung treatments. We have used the DIRART implementations (27) of these algorithms as these are freely available in the public domain and, thus, the present approach may be easily reproduced by interested readers. Furthermore, the calculated deformation vector fields (DVF) are accessible to the user for application to dose warping, which may not necessarily be the case for commercial software algorithms.…”
Section: Methodsmentioning
confidence: 99%