2020
DOI: 10.1093/dote/doaa055
|View full text |Cite
|
Sign up to set email alerts
|

Technical details of the hand-sewn and circular-stapled anastomosis in robot-assisted minimally invasive esophagectomy

Abstract: SUMMARY The circular mechanical and hand-sewn intrathoracic anastomosis are most often used in robot-assisted minimally invasive esophagectomy (RAMIE). The aim of this study was to describe the technical details of both techniques that were pioneered in two high volume centers for RAMIE. A prospectively maintained database was used to identify patients with esophageal cancer who underwent RAMIE with intrathoracic anastomosis. The primary outcome was anastomotic leakage, which was analyzed using … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
24
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(26 citation statements)
references
References 24 publications
0
24
0
2
Order By: Relevance
“…The current results from leading esophagus surgery centers support the use of a circular stapler esophagogastrostomy, especially for minimally invasive intrathoracic anastomosis [5,22]. The stapler diameter should be selected according to the individual anatomical situation of the patient but with preference for the largest possible diameter; however, a significant difference regarding anastomotic leakage and stricture was not identified between 25-and 28-mm diameter sizes [29].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The current results from leading esophagus surgery centers support the use of a circular stapler esophagogastrostomy, especially for minimally invasive intrathoracic anastomosis [5,22]. The stapler diameter should be selected according to the individual anatomical situation of the patient but with preference for the largest possible diameter; however, a significant difference regarding anastomotic leakage and stricture was not identified between 25-and 28-mm diameter sizes [29].…”
Section: Discussionmentioning
confidence: 99%
“…Although several techniques of reconstruction after MIE have been reported, the majority of European centers favor minimally invasive intrathoracic esophagogastrostomy [14,35]. The use of a circular stapler appears to be advantageous with regard to the AL rate, although this question has not yet been conclusively clarified [5]. Experienced centers have published the first larger single-center reports of RAMIE with excellent oncological results and low mortality rates of 1-3% [25,33].…”
Section: Introductionmentioning
confidence: 99%
“…In this regard, as Robot-Assisted Surgery (RAS) has been developed to overcome some of the main drawbacks of pure laparoscopy, especially the bi-dimensional vision and the kinematics limitations; by allowing a finer dissection into mediastinum and more precise suturing, it is expected to bring advantages also for fashioning esophago-gastric anastomosis [10][11][12][13][14][15]. However so far, no data are available to confirm if this expectation for RAS does translate into tangible results for esophageal surgery.…”
mentioning
confidence: 99%
“…Entscheidend für das Outcome scheint auch die Anastomosentechnik zu sein. So erwies sich in mehreren Studien die Rekonstruktion nach Ivor Lewis mit Magenschlauchhochzug und hoher intrathorakaler Zirkularstapleranastomose im Vergleich zu anderen Rekonstruktionstechniken als überlegen [5,26]. Aufgrund der dreidimensionalen Sicht, einer zitterfreien Bewegungsübertragung und dem größeren Freiheitsgrad der Instrumente im Thorax und Mediastinum sind roboterassistierte Verfahren den konventionellen minimalinvasiven Verfahren möglicherweise überlegen [11].…”
Section: Hintergrundunclassified