2015
DOI: 10.3109/14992027.2015.1051665
|View full text |Cite
|
Sign up to set email alerts
|

Technical design of a new bone conduction implant (BCI) system

Abstract: This study shows that the BCI is a robust design that gives a sufficiently high output and an excellent sound quality for the hearing rehabilitation of indicated patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 22 publications
(21 citation statements)
references
References 39 publications
(48 reference statements)
0
21
0
Order By: Relevance
“…No automatic features were activated but modest compression for high level sounds was used in some patients, decided in the interaction between the patient and the operator. A more detailed description of the digital signal processor used can be found in Taghavi et al (2015). All patients were provided with up to four programmes with different frequency characteristics to be tested in various listening situations.…”
Section: Fitting Of the Audio Processormentioning
confidence: 99%
See 1 more Smart Citation
“…No automatic features were activated but modest compression for high level sounds was used in some patients, decided in the interaction between the patient and the operator. A more detailed description of the digital signal processor used can be found in Taghavi et al (2015). All patients were provided with up to four programmes with different frequency characteristics to be tested in various listening situations.…”
Section: Fitting Of the Audio Processormentioning
confidence: 99%
“…However, the present BCI design is just the first generation of direct bone drive transcutaneous induction devices and future power models may be expected to offer additional maximum output and other prescription rules allowing for a more sophisticated use of compression. Theoretically, 6 dB increased maximum force level output may be achieved by using a full bridge instead of the present half bridge power stage as used today (Taghavi et al 2015).…”
Section: Effectivenessmentioning
confidence: 99%
“…The BCI Best Transducer (Oticon Company, Figure 17) consists of an external audio-processor and the implant called Bridging Bone Conductor, a magnet, the receiver coil, and the transducer. The units communicate via an inductive connection through the intact skin [128], [129]. Advantages: MRI compatible to 1.5 T.…”
Section: Active Transcutaneous Systems 4221 Oticon Bci Best Transdmentioning
confidence: 99%
“…The bone conduction implant (BCI) is an active transcutaneous BCD and consists of an implanted part including the receiver coil, the retention magnet and the transducer, and an audio processor, which is retained on the skin by magnetic force [Hakansson et al, 2010;Taghavi et al, 2015] (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%