Technical Considerations and Practical Guidance for Intracoronary Optical Coherence Tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 42 publications
0
3
0
Order By: Relevance
“…The 'Survey' mode provides a rapid pullback of 75 mm over 2.1 s at 180 frames per second (i.e., in 5 frames/mm). The 'High Resolution' mode images a 54 mm segment at the same frame rate over 3 s (i.e., 10 frames/mm), having twice the frame density [18]. Our analysis showed that the 54 mm 'High Resolution' mode was heavily preferred (74% vs 26%) over the 75 mm 'Survey' mode resulting in significant higher frequency of incomplete ROI in the 54-mm pullbacks (18.2% vs 10%; p = 0.02).…”
Section: Discussionmentioning
confidence: 99%
“…The 'Survey' mode provides a rapid pullback of 75 mm over 2.1 s at 180 frames per second (i.e., in 5 frames/mm). The 'High Resolution' mode images a 54 mm segment at the same frame rate over 3 s (i.e., 10 frames/mm), having twice the frame density [18]. Our analysis showed that the 54 mm 'High Resolution' mode was heavily preferred (74% vs 26%) over the 75 mm 'Survey' mode resulting in significant higher frequency of incomplete ROI in the 54-mm pullbacks (18.2% vs 10%; p = 0.02).…”
Section: Discussionmentioning
confidence: 99%
“…OCT images are noisier along the longitudinal direction than in the cross-sectional planes. Indeed, the in-plane noise due to the cardiac motion is small, at a frame rate of 100 frame/s in the current OCT platforms, compared to the noise due to the relative cardiac motion in the longitudinal direction with a pullback speed of about 10-40 mm/s [29,56]. Notice that the longitudinal resolution (and thus the point cloud density in z) is primarily a function of the sampling rate and the pullback speed.…”
Section: Skeletonizationmentioning
confidence: 93%
“…More precisely, the density of points along the in-plane coordinates (x and y in the L-view) is generally much higher than along the longitudinal (z in the L-view) direction. Considering that the longitudinal resolution is between 0.1 and 0.2 mm, while in each frame, we have a point with a linear density of about 0.01 mm [29], the D SSD definition (2) addresses this anisotropy. OCT images are noisier along the longitudinal direction than in the cross-sectional planes.…”
Section: Skeletonizationmentioning