2000
DOI: 10.1097/00003072-200012000-00003
|View full text |Cite
|
Sign up to set email alerts
|

Technical Aspects of Performing Lymphoscintigraphy

Abstract: Sentinel node detection is an important part of the clinical management of newly diagnosed melanoma. Now there is a similar or even greater enthusiasm for sentinel node evaluation in patients with breast carcinoma. However, controversies exist regarding the dose, volume, and route of administration. Even the role of lymphoscintigraphy itself, in contrast to using only a hand-held gamma probe during surgery for sentinel node detection, is being debated. Nevertheless, many centers and surgeons find that lymphosc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
3
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(6 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…However, plain lymphoscintigraphy images do not show any anatomical detail or exact location of the sentinel nodes in axilla which are very important factors for surgery planning 4. Skin pen marking1, stereoscopic lymphoscintigraphy5 and body outlining6 are three solutions to deal with this problem. Several methods are in use for outlining the body contour during lymphoscintigrpahy imaging with their own advantages and drawbacks 7.…”
Section: Introductionmentioning
confidence: 99%
“…However, plain lymphoscintigraphy images do not show any anatomical detail or exact location of the sentinel nodes in axilla which are very important factors for surgery planning 4. Skin pen marking1, stereoscopic lymphoscintigraphy5 and body outlining6 are three solutions to deal with this problem. Several methods are in use for outlining the body contour during lymphoscintigrpahy imaging with their own advantages and drawbacks 7.…”
Section: Introductionmentioning
confidence: 99%
“…Image acquisition when the patient's arm is 90 from the long axis of the patient to simulate the surgical position has been discussed. Because of the impracticality of obtaining lateral views, arm angles of between 135 and 180 have been suggested as a compromise (8). However, this is also not the native position of the surgery.…”
Section: Discussionmentioning
confidence: 99%
“…However, this positioning is not practical for image acquisitions in 2 different views using a dual-head camera. Also, oblique images may be more difficult to interpret (8). Image acquisitions in a prone position with the breast hanging using a special pad with cutouts to move the injection site away from the axilla has been described.…”
Section: Discussionmentioning
confidence: 99%
“…However, radioisotope shows some inherent limitations. It has been reported to cause moderate and severe pain at the site of injection in many patients 23 . Moreover, the suboptimal spatial resolution of the detecting system and the lack of anatomic landmarks showing on the monitor hinder the accuracy of lymph node localization and numbers assessed even by experienced surgeons.…”
Section: Discussionmentioning
confidence: 99%