2019
DOI: 10.1016/j.corsci.2019.03.035
|View full text |Cite
|
Sign up to set email alerts
|

Task-specific ionic liquids as corrosion inhibitors on carbon steel in 0.5 M HCl solution: An experimental and theoretical study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
51
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 146 publications
(51 citation statements)
references
References 48 publications
0
51
0
Order By: Relevance
“…As indicated by the calculated values of C dl ( Table 1 ), the corrosion mitigation is due to the adsorption of the inhibitor molecules that apparently blocked the steel surface active sites in the studied medium. 26 , 27 Furthermore, the corrosion potential ( E corr ) is slightly shifted toward a more noble potential in both Figure 4 a,b. The displacement is, however, more noticeable in Figure 4 b than in Figure 4 a.…”
Section: Results and Discussionmentioning
confidence: 86%
See 1 more Smart Citation
“…As indicated by the calculated values of C dl ( Table 1 ), the corrosion mitigation is due to the adsorption of the inhibitor molecules that apparently blocked the steel surface active sites in the studied medium. 26 , 27 Furthermore, the corrosion potential ( E corr ) is slightly shifted toward a more noble potential in both Figure 4 a,b. The displacement is, however, more noticeable in Figure 4 b than in Figure 4 a.…”
Section: Results and Discussionmentioning
confidence: 86%
“…Furthermore, increase in the concentrations of NDTHDC and poly-NDTHDC to 1000 and 100 mg/L, respectively, further raised the charge-transfer resistances to 137.3 and 388.1 Ω cm 2 and inhibition efficiencies to 57.10 and 84.82% but decreased the C dl values to 0.24 and 0.10 μF/cm 2 , respectively. This infers that the adsorption of the inhibitor molecules reduced the capacitance through the increase in the double-layer thickness ( , where ε 0 is the permittivity of air, ε is the local dielectric constant, d is the film thickness, and S is the electrode surface 26 ). It is also important to point out the smaller values of C dl in the systems inhibited with poly-NDTHDC than in systems protected with NDTHDC ( Table 1 ).…”
Section: Results and Discussionmentioning
confidence: 99%
“…Considerations of these features of corrosion inhibitors have led to the evaluations of numerous biological materials for effective corrosion inhibitors [11][12][13][14][15][16][17][18] due to their non-toxicity and biodegradable properties. Furthermore, novel ionic liquids [19][20][21] and some eco-friendly organic compounds containing different forms of functional groups, heteroaryl, aromatics cycles, saturated and unsaturated bonds in their molecular structures [22][23][24][25][26][27] have been reported as effective corrosion inhibitors.…”
Section: Introductionmentioning
confidence: 99%
“…Ionic liquids (ILs) have been identified as green solvents with low melting point, negligible vapor pressure, excellent thermal stability, and high solubility [15][16][17]. Therefore, ILs received extensive attention as green corrosion inhibitors [18][19][20][21].…”
Section: Introductionmentioning
confidence: 99%