2015
DOI: 10.1016/j.jchromb.2015.07.046
|View full text |Cite
|
Sign up to set email alerts
|

Target-guided separation of antioxidants from Semen cassia via off-line two-dimensional high-speed counter-current chromatography combined with complexation and extrusion elution mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 45 publications
0
13
0
Order By: Relevance
“…As shown in Figure 3B, seven compounds showed peak area reduction (PAR) between 13.6%–37.4%. In addition, Zeng et al reported that the rear eluting peak of the 34-min retention time is of DPPH [15]. Among these seven compounds, AM and QU (PAR 23%–37%) would be more potent antioxidants than RT, LGC, LGN, AGC and AGN, which showed PAR lower than 20.0%.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As shown in Figure 3B, seven compounds showed peak area reduction (PAR) between 13.6%–37.4%. In addition, Zeng et al reported that the rear eluting peak of the 34-min retention time is of DPPH [15]. Among these seven compounds, AM and QU (PAR 23%–37%) would be more potent antioxidants than RT, LGC, LGN, AGC and AGN, which showed PAR lower than 20.0%.…”
Section: Resultsmentioning
confidence: 99%
“…These methods required an online instrumental system and technical skills that were complex and available. Recently, the more convenient offline DPPH-HPLC method was successfully developed by spiking the complex plant extracts [15,16]. …”
Section: Introductionmentioning
confidence: 99%
“…The peak area of the upper phase was recorded as A U (area of the upper phase) and that of the lower phase was recorded as A L (area of the lower phase). The K value was calculated according to the equation K = A U / A L [ 32 , 33 ].…”
Section: Methodsmentioning
confidence: 99%
“…Combination of CCC and HPLC, also named as 2D chromatography, provides an even more robust and versatile methods for separation of complex matrix, which has been increasingly explored in separation of different natural Article Related Abbreviations: CCC, countercurrent chromatography; 1 D, first dimension; 2 D, second dimension. The heart-cut mode of 2D separation has been focused on the optimization of biphasic solvent system, improving of equipment, and the combination with the detector of ESI-MS/NMR spectroscopy [10][11][12][13][14][15][16][17][18]. On-line comprehensive 2D chromatography has been conventionally applied in gas chromatography (GC × GC) and liquid chromatography (LC×LC) and they have been well studied because of their powerful separation efficiency for complex samples [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…Up to 2016, 2D CCC separation of complex samples had been conducted only by heart-cut mode, that is to say, a limited number of fractions were collected from 1 D and transferred physically into 2 D separation. The heart-cut mode of 2D separation has been focused on the optimization of biphasic solvent system, improving of equipment, and the combination with the detector of ESI-MS/NMR spectroscopy [10][11][12][13][14][15][16][17][18]. However, the maximum potentiality in 2D chromatography CCC-HPLC with heart-cut mode was limited owing to the low peak capacity [19].…”
Section: Introductionmentioning
confidence: 99%