2015
DOI: 10.1373/clinchem.2015.242560
|View full text |Cite
|
Sign up to set email alerts
|

Tandem Mass Spectrometry Has a Larger Analytical Range than Fluorescence Assays of Lysosomal Enzymes: Application to Newborn Screening and Diagnosis of Mucopolysaccharidoses Types II, IVA, and VI

Abstract: BACKGROUND There is interest in newborn screening and diagnosis of lysosomal storage diseases because of the development of treatment options that improve clinical outcome. Assays of lysosomal enzymes with high analytical range (ratio of assay response from the enzymatic reaction divided by the assay response due to nonenzymatic processes) are desirable because they are predicted to lead to a lower rate of false positives in population screening and to more accurate diagnoses. METHODS We designed new tandem … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
93
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 56 publications
(94 citation statements)
references
References 26 publications
1
93
0
Order By: Relevance
“…The analytical range was defined as the enzyme-dependent assay response from the pooled normal control sample divided by the assay response for all GAA-independent processes (13). We anticipate that assays with a higher analytical range will be more accurate since the enzymatic activity values are spread over a larger range.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The analytical range was defined as the enzyme-dependent assay response from the pooled normal control sample divided by the assay response for all GAA-independent processes (13). We anticipate that assays with a higher analytical range will be more accurate since the enzymatic activity values are spread over a larger range.…”
Section: Resultsmentioning
confidence: 99%
“…For MS/MS assays, the analytical range was calculated as: (GAA activity for normal control sample) − (GAA activity of the blank assay without leukocyte lysate)/(GAA activity of the assay without leukocyte lysate) (13). By using leukocyte lysates from non-Pompe pools, the analytical range for the LC-MS/MS assay of GAA was found to have a mean (SD) of 1135 (539) (see online Supplemental Table 3).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Direct screening examines endogenous substances, while indirect screening focusses on the conversion of substrates by specific enzymes 39 . Current NBS programs screen for up to over 50 disorders 40,41 .…”
Section: Alternative Sampling Strategiesmentioning
confidence: 99%