1993
DOI: 10.1259/0007-1285-66-789-783
|View full text |Cite
|
Sign up to set email alerts
|

T1ρ dispersion imaging of diseased muscle tissue

Abstract: T1 rho dispersion, or the frequency dependence of T1 relaxation in the rotating frame, was used for in vivo muscle tissue characterization in 13 patients with primary skeletal muscle disease and in eight normal subjects for comparison. T1 rho dispersion measurements represent a new approach to magnetic resonance tissue characterization, possibly reflecting the macromolecular constituents of tissue. A definite, statistically significant, difference was found between the relative T1 rho dispersion values of norm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
24
0

Year Published

1996
1996
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(24 citation statements)
references
References 22 publications
0
24
0
Order By: Relevance
“…T 1r studies in solution-state NMR have been reviewed extensively (166)(167)(168). There has been a considerable amount of work on biological tissues using T 1r -spectroscopy and imaging dealing with tumors, muscle, myocardium, blood flow and cartilage (26,165,(169)(170)(171)(172)(173)(174)(175)(176)(177)(178)(179).…”
Section: T 1r Mrimentioning
confidence: 99%
“…T 1r studies in solution-state NMR have been reviewed extensively (166)(167)(168). There has been a considerable amount of work on biological tissues using T 1r -spectroscopy and imaging dealing with tumors, muscle, myocardium, blood flow and cartilage (26,165,(169)(170)(171)(172)(173)(174)(175)(176)(177)(178)(179).…”
Section: T 1r Mrimentioning
confidence: 99%
“…For an on-resonance RF field with the given input parameters, the saturated magnetization, M sat , is described by Eq. [2] with the equilibrium term M equilibrium sat , coefficients c 1 , c 2 , c 3 , and with constant terms 1 , 2 , 3 . ) and is nutated into the y-axis by the initial hard 90°along the x-axis.…”
Section: Saturation Modelmentioning
confidence: 99%
“…[1], the T 1 parameter can be measured on a pixelby-pixel basis using linear regression to create a quantitative spatial map of T 1 values. SL pulse sequences may be applicable for imaging multiple systems, such as muscle (1,2), breast (3), liver (4), brain (5,6), and tumors (7,8). T 1 relaxation has been used as an indicator of proteoglycan content in articular cartilage, and is being developed as a diagnostic tool for the detection of osteoarthritis (9 -12).…”
mentioning
confidence: 99%
“…Spin-lock MRI is of interest in the study of many biologic systems including muscle (5,6), breast (7), liver (8,9), brain (10,11), tumors (12)(13)(14), and cartilage (15)(16)(17)(18). Quantifica tion of the T 1 parameter has been shown to provide a noninvasive measure of physiologic parameters such as blood perfusion (19,20) and macromolecular content (17,21).…”
mentioning
confidence: 99%