2022
DOI: 10.1016/j.ssnmr.2022.101807
|View full text |Cite
|
Sign up to set email alerts
|

t1-noise elimination by continuous chemical shift anisotropy refocusing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 61 publications
1
5
0
Order By: Relevance
“…A 1 H{ 11 B} dipolar heteronuclear multiple-quantum correlation (D-HMQC) 70 spectrum was acquired using the CSA-free SR6 2 3 recoupling sequence. 42 This spectrum (shown in Figure S12) shows a correlation between the B(B)O 2 11 B NMR signal and 1 H sites resonating at 3.2 ppm, in agreement with their assignment as B−OH protons.…”
Section: Layer Terminationsupporting
confidence: 73%
See 1 more Smart Citation
“…A 1 H{ 11 B} dipolar heteronuclear multiple-quantum correlation (D-HMQC) 70 spectrum was acquired using the CSA-free SR6 2 3 recoupling sequence. 42 This spectrum (shown in Figure S12) shows a correlation between the B(B)O 2 11 B NMR signal and 1 H sites resonating at 3.2 ppm, in agreement with their assignment as B−OH protons.…”
Section: Layer Terminationsupporting
confidence: 73%
“…The energy-dispersive X-ray spectroscopy (EDS) mapping data were collected with a Super-X EDS detector. recoupling sequence 42 with a 47.6191 kHz MAS frequency. 11 B pulses utilized an effective rf field of 50 kHz, and hard 1 H pulses had an rf field of 100 kHz.…”
Section: Scanning Transmission Electron Microscopy (Stem)mentioning
confidence: 99%
“…55 Indirect detection of 89 Y using D-HMQC was recently reported for the metal organic framework phase Y-MOF-76, which compared approaches to refocus CSA effects and reduce t 1 -noise. 57…”
Section: Recent Advances In Solid-state Nmr Methodologymentioning
confidence: 99%
“…55 Indirect detection of 89 Y using D-HMQC was recently reported for the metal organic framework phase Y-MOF-76, which compared approaches to refocus CSA effects and reduce t 1 -noise. 57 To gain even more in signal DNP has recently been combined with indirect detection, which has become possible with the availability of low-temperature fast MAS probes. A detailed theoretical and experimental study with DNP-enhanced 2D indirectly detected HETCOR (idHETCOR) experiments on four spin- 1 2 nuclei ( 13 C, 15 N, 113 Cd, 89 Y), with 1.3 and 3.2 mm probes used.…”
Section: Techniques For Sensitivity Enhancementmentioning
confidence: 99%
See 1 more Smart Citation