2020
DOI: 10.1186/s12968-020-00613-3
|View full text |Cite
|
Sign up to set email alerts
|

T1 mapping performance and measurement repeatability: results from the multi-national T1 mapping standardization phantom program (T1MES)

Abstract: Background: The T 1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T 1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T 1 measurement repeatability across centers describing sequence, magnet, and vendor performance. Methods: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B 0 and B 1 , and "reference" slow T 1 testing. Temperatu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
30
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 25 publications
(31 citation statements)
references
References 33 publications
1
30
0
Order By: Relevance
“…This used the T1 Mapping and ECV Standardization (T1MES) phantom and analysis pipeline. 25 , 26 At the time of COVID patient scanning (September to October 2020), the same phantom was transported between the four scanners in this study (all Siemens Aera 1.5T). After a minimum 8 h equilibrium in the magnet room at each site, the phantom was scanned according to the protocol specified in the T1MES user manual.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This used the T1 Mapping and ECV Standardization (T1MES) phantom and analysis pipeline. 25 , 26 At the time of COVID patient scanning (September to October 2020), the same phantom was transported between the four scanners in this study (all Siemens Aera 1.5T). After a minimum 8 h equilibrium in the magnet room at each site, the phantom was scanned according to the protocol specified in the T1MES user manual.…”
Section: Methodsmentioning
confidence: 99%
“…After a minimum 8 h equilibrium in the magnet room at each site, the phantom was scanned according to the protocol specified in the T1MES user manual. 26 …”
Section: Methodsmentioning
confidence: 99%
“…ECV was derived using a same-day hematocrit. Magnet quality assurance used the T1MES phantom to ensure no differences between the 3 magnets and no temporal drift ( 25 , 26 ). Across the 3 magnets, temperature-corrected T 1 and T 2 was within 0.33% and 0.95%, respectively, with temporal drift of <1% ( Supplemental Methods ).…”
Section: Methodsmentioning
confidence: 99%
“…Nevertheless, there is no current standard and reference sequence for T1 or T2 mapping that is widely accepted and distributed. However, standardization initiatives such as the “T1MES” phantom project are promising approaches to increase quality assurance of mapping sequences [ 56 ].…”
Section: Edema Imaging To Differentiate Between Acute and Chronic Myomentioning
confidence: 99%