T1D‐weighted ihMT imaging – Part I. Isolation of long‐ and short‐T1D components by T1D‐filtering

Abstract: To identify T 1D -filtering methods, which can specifically isolate various ranges of T 1D components as they may be sensitive to different microstructural properties.Methods: Modified Bloch-Provotorov equations describing a bi-T 1D component biophysical model were used to simulate the inhomogeneous magnetization transfer (ihMT) signal from ihMTRAGE sequences at high RF power and low duty-cycle with different switching time values for the dual saturation experiment: Δt = 0.0, 0.8, 1.6, and 3.2 ms. Simulations … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 41 publications
1
9
0
Order By: Relevance
“…Because the ihMT increase with reduced duty cycle can be very large, greater than 3-fold, the use of low duty cycle preparations to achieve higher signal and SNR is becoming increasingly preferred. With high RF saturation power, which is typically the case for low duty cycle experiments, the signal contribution from shorter T 1D molecules can become substantial, 38,44,49,50 opening the possibility to image other molecular structures and tissues than myelin. 51,52 The increased sensitivity to short T 1D s does reduce the specificity of the ihMT signal to myelin, however.…”
Section: Optimizing Acquisition Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Because the ihMT increase with reduced duty cycle can be very large, greater than 3-fold, the use of low duty cycle preparations to achieve higher signal and SNR is becoming increasingly preferred. With high RF saturation power, which is typically the case for low duty cycle experiments, the signal contribution from shorter T 1D molecules can become substantial, 38,44,49,50 opening the possibility to image other molecular structures and tissues than myelin. 51,52 The increased sensitivity to short T 1D s does reduce the specificity of the ihMT signal to myelin, however.…”
Section: Optimizing Acquisition Methodsmentioning
confidence: 99%
“…45 The T 1D -filtering principle relies on the sensitivity of ihMT to T 1D when using frequency-alternated pulses with different switching times, τ switch , for the dual-offset saturation experiment (Figure 4), and has been recently characterized. 44 The lengthening of τ switch efficiently attenuates the signal associated with T 1D values shorter than τ switch (even eliminates their contribution when T 1D << τ switch ), thereby generating an ihMT high-pass T 1D filter with increasing cutoff values (Figure 5A). IhMT high-pass T 1D filters with high cutoff values can selectively image longer T 1D contributors and increase the WM/GM contrast (Figure 5C).…”
Section: Estimating Validating Separating and Interpreting Different ...mentioning
confidence: 99%
See 3 more Smart Citations