2023
DOI: 10.59277/rrst-ee.2023.4.15
|View full text |Cite
|
Sign up to set email alerts
|

Système Intelligent Pour La Réduction De La Consommation Électrique en Veille Des Équipements Ménagers

ANDREI-COSMIN GHOERGHE,
HORIA ANDREI,
EMIL DIACONU
et al.

Abstract: L’une des caractéristiques des équipements électroménagers est qu’ils consomment également de l’énergie en mode veille, ce qui peut prendre des quantités considérables dans le temps. Un système intelligent capable de couper automatiquement l'alimentation électrique de l'équipement en mode veille doit être important pour réduire la consommation électrique et les dépenses financières. Pour concevoir le système, la consommation électrique en mode veille de 3 équipements ménagers de base a été mesurée dans un prem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 23 publications
1
3
0
Order By: Relevance
“…By analyzing the graphs of the time variations of the current and the power absorbed by the same electrical household equipment-a washing machine and a laptop-made with Fluke, one can see the similarity with those accomplished with the DAQ system proposed in this article. Moreover, the measurements made with HLW8032 compared to those presented in previous articles [17,18] using the first version of the DAQ system showed identical values.…”
Section: Standby Power Consumption Data Measurementsupporting
confidence: 67%
See 3 more Smart Citations
“…By analyzing the graphs of the time variations of the current and the power absorbed by the same electrical household equipment-a washing machine and a laptop-made with Fluke, one can see the similarity with those accomplished with the DAQ system proposed in this article. Moreover, the measurements made with HLW8032 compared to those presented in previous articles [17,18] using the first version of the DAQ system showed identical values.…”
Section: Standby Power Consumption Data Measurementsupporting
confidence: 67%
“…chosen to compare the obtained results with those presented in previous articles [17] and [18] which were achieved with another DAQ. The DAQ system mentioned in the previous articles was composed of two current sensors (LCSC ZHT103 that was sourced from Guangdong, China and Allegro Microsystem s ACS712 that was sourced from Guangdong, China) and a voltage sensor (LCSC ZMPT101B that was sourced from Guangdong, China).…”
Section: Data Measurement and Matlab Interpolation Of Washing Machine...mentioning
confidence: 90%
See 2 more Smart Citations