2007
DOI: 10.1016/j.biomaterials.2007.04.044
|View full text |Cite
|
Sign up to set email alerts
|

Systematic review of the chemical composition of contemporary dental adhesives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

15
1,131
2
165

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 1,131 publications
(1,313 citation statements)
references
References 159 publications
15
1,131
2
165
Order By: Relevance
“…Earlier studies found that the resin with high penetration coefficients could penetrate deeper inside the lesion 20,21) . The ICON resin monomer (TEGDMA) contains no functional group in the molecule to exert strong chemical bonding performance to the apatite surface such as esterized phosphate, e.g., methacryloyloxydecyl dihydrogen phosphate (MDP) 22) and carboxy groups e.g., 4-methacryloxyethyl trimellitate anhydride (4-META) 23) . Thus, it is believed that TEGDMA does not have the ability to adhere to teeth 24) .…”
Section: Discussionmentioning
confidence: 99%
“…Earlier studies found that the resin with high penetration coefficients could penetrate deeper inside the lesion 20,21) . The ICON resin monomer (TEGDMA) contains no functional group in the molecule to exert strong chemical bonding performance to the apatite surface such as esterized phosphate, e.g., methacryloyloxydecyl dihydrogen phosphate (MDP) 22) and carboxy groups e.g., 4-methacryloxyethyl trimellitate anhydride (4-META) 23) . Thus, it is believed that TEGDMA does not have the ability to adhere to teeth 24) .…”
Section: Discussionmentioning
confidence: 99%
“…oxidation of residual monomer) [9,10]. In this respect, the resin matrix composition with its hydrophilicity/hydrophobicity, filler load, size and nature of the particles [11], quantity of photo-initiator or inhibitor [12] and degree of conversion [13] have a strong influence on the stain intensity of composite resin.…”
Section: Introductionmentioning
confidence: 99%
“…TMSBr was distilled prior to use. KOCN and NBu 4 Br were dried at 100°C under vacuum (0.1 mbar for KOCN and 3 mbar for NBu 4 Br) for 4 h prior to use. IEM was purchased from ABCR (Germany).…”
Section: Methodsmentioning
confidence: 99%
“…[2][3][4] Contrary to the total-etch systems, which require the use of a phosphoric acid gel prior to the application of the adhesive, SEAs do not need a separate etching step. SEAs are aqueous solutions containing an acidic monomer (carboxylic acid, dihydrogen phosphate, phosphonic acid) as well as various monofunctional and crosslinking comonomers.…”
Section: Introductionmentioning
confidence: 99%