Systematic intensity errors and model imperfection as the consequence of spectral truncation

Abstract: The wavelength dispersion delta lambda/lambda in a graphite (002) monochromated Mo K alpha beam was analyzed. A wavelength window was found with 0.68 < lambda < 0.79 A, i.e. delta lambda/lambda = 0.14. The very large dispersion leads to systematic errors in Iobserved(H) caused by scan-angle-induced spectral truncation. A limit on the scan angle during data collection is unavoidable, in order that an omega/2 theta measurement should not encompass neighboring reflections. The systematic intensity errors increase… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
26
0

Year Published

2001
2001
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(29 citation statements)
references
References 8 publications
2
26
0
Order By: Relevance
“…The magnitude of the difference between U͑␥ ray͒ and U͑x ray͒ is of the same size as the values reported in Ref. 15 for Mo K␣ radiation. The spectral width of the 316.5 keV photon beam is ⌬/ϭ10 Ϫ6 and no monochromator is needed.…”
Section: A Vibrational Parameterssupporting
confidence: 78%
See 1 more Smart Citation
“…The magnitude of the difference between U͑␥ ray͒ and U͑x ray͒ is of the same size as the values reported in Ref. 15 for Mo K␣ radiation. The spectral width of the 316.5 keV photon beam is ⌬/ϭ10 Ϫ6 and no monochromator is needed.…”
Section: A Vibrational Parameterssupporting
confidence: 78%
“…It has been recognized only recently that a graphite monochromated x-ray beam contains a Bremsstrahlung component with a large wavelength spread. 15 This fully contributes to the measured intensity at low Bragg angles and is progressively truncated at higher angles. The truncation depends on the tube voltage and leads to vibrational parameters which are systematically too large by about 30% for usual conditions.…”
Section: A Vibrational Parametersmentioning
confidence: 92%
“…The discrepancy is due to the reduced monochromaticity of a graphite monochromated x-ray beam. 20 It contains a bremsstrahlung component with a large wavelength spread that fully contributes to the measured intensity at low Bragg angles and is progressively truncated at higher angles. The contribution of the bremsstrahlung depends on the tube voltage and leads to vibrational parameters that are systematically too large.…”
Section: A Vibrational Parametersmentioning
confidence: 99%
“…Theoretical analysis showed that the spectra of Ni(OH 2 ) 6 2+ are sensitive to the O-Ni distances in the octahedral unit [12]. The average O-Ni distance calculated (Table 2) is 2.061Å for ZNSH, 2.049 Å for NSH [13] and surely a large distance for units in solution. We can infer the energy splittings between the nonequivalent d orbitals of octahedral unit in crystals are comparatively notable and it yields the blue shifts for transmission at UV and VIS region.…”