12th International Energy Conversion Engineering Conference 2014
DOI: 10.2514/6.2014-3966
|View full text |Cite
|
Sign up to set email alerts
|

System-level Testing of the Advanced Stirling Radioisotope Generator Engineering Hardware

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Further refinements to the DC bus voltage compensation algorithm could reduce the sensitivities. 8 The EDU 4.1 sensitivities were significantly smaller than sensitivities observed during EU testing with EDU 1.…”
Section: F DC Bus Voltage Variationmentioning
confidence: 80%
“…Further refinements to the DC bus voltage compensation algorithm could reduce the sensitivities. 8 The EDU 4.1 sensitivities were significantly smaller than sensitivities observed during EU testing with EDU 1.…”
Section: F DC Bus Voltage Variationmentioning
confidence: 80%
“…The units were then provided to Lockheed Martin for successful controller functional testing. 8 The units have been returned to GRC, completed receipt checkout tests, and are being prepared for integration into the ASRG EU2. The ASC-E3 Pair 1 convertors have each accumulated over 3,100 hours of operation at GRC with steady flat-line performance.…”
Section: B Continued Asc-e3 Production At Sunpower and Asrg Eu2 Assembly At Grcmentioning
confidence: 99%
“…Despite the promised high power, a mechanical system may not have the longevity for deep space missions . [28][29][30][31][32][33][34][35][36] Figure 1. Comparison of conventional semiconductor-based thermoelectric concept (a) to the new metallic junction thermoelectric concept (b).…”
Section: Introductionmentioning
confidence: 99%