1989
DOI: 10.1016/0011-9164(89)85009-x
|View full text |Cite
|
Sign up to set email alerts
|

System identification and control of reverse osmosis desalination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
24
0
2

Year Published

2008
2008
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 79 publications
(27 citation statements)
references
References 4 publications
1
24
0
2
Order By: Relevance
“…Many researchers have suggested identified transfer functions from input/output data of RO process. MIMO structure of RO plant at Doha can be given by Alatiqi et al (1989) using system identification techniques as Y 1 Y 2 Â Ã ¼ 0:007ð0:056sþ1Þ 0:213s 2 þ0:7sþ1 0 À7:3ð0:35sþ1Þ 0:213s 2 þ0:7sþ1…”
Section: Calculates Fluxes and Permeate Concentrationmentioning
confidence: 99%
See 2 more Smart Citations
“…Many researchers have suggested identified transfer functions from input/output data of RO process. MIMO structure of RO plant at Doha can be given by Alatiqi et al (1989) using system identification techniques as Y 1 Y 2 Â Ã ¼ 0:007ð0:056sþ1Þ 0:213s 2 þ0:7sþ1 0 À7:3ð0:35sþ1Þ 0:213s 2 þ0:7sþ1…”
Section: Calculates Fluxes and Permeate Concentrationmentioning
confidence: 99%
“…The process variables are identified already and categorized under control variables (permeate salinity and permeate flow rate) and manipulated variables (feed pH and feed pump pressure). Results with conventional PI (Alatiqi et al 1989) and model predictive control are available in literature. According to Alatiqi et al (1989), permeates flux and conductivity were controlled by manipulating feed pressure and pH.…”
Section: Identificationmentioning
confidence: 99%
See 1 more Smart Citation
“…And, only two of these are considered in the control system developed, namely, the flow rates of the acid and the retentate streams. [12] We use a similar flowsheet representation throughout this article, where, in all the figures the thin and thick lines represent material and energy streams, respectively.…”
Section: Restraining Number For Membrane Separatorsmentioning
confidence: 99%
“…The first paper which proposed an effective closed-loop control strategy for RO utilized multiple single-input single-output (SISO) classical (i.e., proportional, integral, derivative (PID)) control loops. 3 Within a model-based control setting, step tests were used to perform system identification, resulting in a model that is a linear approximation around the operating point. The control algorithm of model predictive control (MPC) was applied to the resulting linear model.…”
Section: Introductionmentioning
confidence: 99%