2018
DOI: 10.1364/ao.57.010218
|View full text |Cite
|
Sign up to set email alerts
|

System design for a “checkerboard” imager

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 3 publications
0
10
0
Order By: Relevance
“…13 The checkerboard arrangement method can realize uniform and nonredundant sampling of the spatial frequency of integer multiples of the fundamental frequency in the two orthogonal array directions. 5 Therefore, this paper adopts the checkerboard imager technical scheme for simulation. The system parameters used in the simulation are shown in Table 1.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…13 The checkerboard arrangement method can realize uniform and nonredundant sampling of the spatial frequency of integer multiples of the fundamental frequency in the two orthogonal array directions. 5 Therefore, this paper adopts the checkerboard imager technical scheme for simulation. The system parameters used in the simulation are shown in Table 1.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
“…The wheel aperture arrangement of SPIDER needs to approximate the annular spatial frequency as a regular two-dimensional grid point during image reconstruction, resulting in errors in the spatial frequency and incomplete sampling of the target spatial frequency domain information 13 . The checkerboard arrangement method can realize uniform and nonredundant sampling of the spatial frequency of integer multiples of the fundamental frequency in the two orthogonal array directions 5 . Therefore, this paper adopts the checkerboard imager technical scheme for simulation.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“… 9 There are also many domestic institutions that have carried out research on SPIDER 10 13 However, the quality of images reconstructed by the segmented planar imaging system still needs to be improved, and there are problems such as low resolution and missing mid- and low-frequency information. Alternatively, increasing the number of mid- and low-frequency samples improves the quality of the reconstructed image.…”
Section: Introductionmentioning
confidence: 99%
“…1(c). To overcome the lack of zero frequency, Yu et al proposed a "checkerboard" design and an aperture matching method, which can acquire a uniform frequency distribution together with the zero frequency [8]. Recently, Yang et al proposed a complex rectangular sub-aperture arrangement method to improve the imaging resolution further [9].…”
Section: Introductionmentioning
confidence: 99%