2012
DOI: 10.1016/j.forsciint.2012.05.027
|View full text |Cite
|
Sign up to set email alerts
|

Synthetic cannabinoids in “spice-like” herbal blends: First appearance of JWH-307 and recurrence of JWH-018 on the German market

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
33
0
1

Year Published

2012
2012
2016
2016

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 46 publications
(35 citation statements)
references
References 10 publications
1
33
0
1
Order By: Relevance
“…MS detector is mostly carried out for SCs detection. Other types in use are nitrogen phosphorus detector (NPD) [4] which is suitable for most types of aminoalkylindoles, and flame ionization detector (FID) [106,107].…”
Section: Gas Chromatographymentioning
confidence: 99%
“…MS detector is mostly carried out for SCs detection. Other types in use are nitrogen phosphorus detector (NPD) [4] which is suitable for most types of aminoalkylindoles, and flame ionization detector (FID) [106,107].…”
Section: Gas Chromatographymentioning
confidence: 99%
“…The other pyrazole derivatives, AM251 and AM281, which are analogs of SR141716A, are also selective CB 1 receptor antagonists [Ki (nM) values = 7.5 and 12, respectively] [20,21]. On the other hand, a pyrrole derivative of synthetic cannabinoid JWH-307, which was detected in illegal products [22], is known to have affinity for CB 1 and CB 2 receptors [Ki (nM) values = 7.7 and 7.1, respectively] [23]. Some detected types of synthetic cannabinoids were reported to have affinities for CB 1 and/or CB 2 receptors [23].…”
Section: Forensic Toxicolmentioning
confidence: 99%
“…This established protocol was facilitated by the fact that the concentration of synthetic cannabinoids is usually of the order of 50-300 mg/g [13,33,34], allowing the use of a single protocol for all samples analyzed, here, using 10 mg of each commercial product. This sample amount requires a final dilution by a factor of 100-200 to meet the dynamic range requirements of our instrumentation.…”
Section: Esi-ms/ms Quantificationmentioning
confidence: 99%
“…The total contents of [25] Quantification was achieved by ESI-MS/MS applying MRM and 3-(3-(1-naphthoyl)-1H-indol-1-yl)propionate as an IS (9). Binding affinities (K i ) for cannabinoid receptor type 1 (CB 1 ) are listed when available a Samples were fluffy greenish plant material; except for sample 5B which was a brown hashish like resin b Mean of two individual extractions and measurements (n = 2) c Numbers reflect the source, letters reflect different products d Diluted in 90 % methanol, 10 % water, 1 % formic acid and 0.1 % ammonium formate Forensic Toxicol synthetic cannabinoids found in the analyzed products ranged from 66 to 446 mg/g, reflecting the ''normal'' range frequently found for such products [13,33,34]. The calculation of the concentration of the synthetic cannabinoids in commercial products depends to a great extent on the RFs.…”
Section: Esi-ms/ms Quantificationmentioning
confidence: 99%