2020
DOI: 10.1016/j.molstruc.2020.128395
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis of new fluorene compounds for highly selective sensing of picric acid, Fe3+ and l-arginine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 35 publications
0
7
0
Order By: Relevance
“…As seen from Fig S5, the uorescence quenching for PA and Fe 3+ was occurred only within just 30 seconds, and at their uorescence intensities were reached to equilibrium at same response time. Thus, a response time was decided on 30 seconds for the following experiments and the chemoprobe IPC depicted an excellent response time towards PA and Fe 3+ respecting the formerly developed a lot of uorogenic dual chemoprobes [10,[19][20][21].…”
Section: Fabrication and Characterization Of Ipcmentioning
confidence: 99%
See 1 more Smart Citation
“…As seen from Fig S5, the uorescence quenching for PA and Fe 3+ was occurred only within just 30 seconds, and at their uorescence intensities were reached to equilibrium at same response time. Thus, a response time was decided on 30 seconds for the following experiments and the chemoprobe IPC depicted an excellent response time towards PA and Fe 3+ respecting the formerly developed a lot of uorogenic dual chemoprobes [10,[19][20][21].…”
Section: Fabrication and Characterization Of Ipcmentioning
confidence: 99%
“…To keep away from these drawbacks, uorescent sensing systems have been recently developed due to their superior advantages mentioned above [7,[16][17][18]. However, the literatures based upon to fabricate dual responsive uorescent chemoprobes for the recognition of both PA and Fe 3+ with high selectivity and sensitivity, are still rare [10,[19][20][21]. Therefore, the need is great for more uorescent chemoprobes able to detect the PA and Fe 3+ in real-time and reliably.…”
Section: Introductionmentioning
confidence: 99%
“…As seen from Fig S5, the uorescence quenching for PA and Fe 3+ was occurred only within just 30 seconds, and at their uorescence intensities were reached to equilibrium at same response time. Thus, a response time was decided on 30 seconds for the following experiments and the chemoprobe IPC depicted an excellent response time towards PA and Fe 3+ respecting the formerly developed a lot of uorogenic dual chemoprobes [10,[19][20][21].…”
Section: Fabrication and Characterization Of Ipcmentioning
confidence: 99%
“…To keep away from these drawbacks, uorescent sensing systems have been recently developed due to their superior advantages mentioned above [7,[16][17][18]. However, the literatures based upon to fabricate dual responsive uorescent chemoprobes for the recognition of both PA and Fe 3+ with high selectivity and sensitivity, are still rare [10,[19][20][21]. Therefore, the need is great for more uorescent chemoprobes able to detect the PA and Fe 3+ in real-time and reliably.…”
Section: Introductionmentioning
confidence: 99%
“…There are numerous small molecule sensors as well to detect PA with low LOD. [42][43][44][45][46][47][48][49][50][51][52][53][54][55][56] Zinc oxide nanomaterials and fluorescent quantum dots were also helpful in PA detection. [57,58] The fluorescent outputs due to the sensing mechanisms were effectively used to prepare logic based devices in some cases.…”
Section: Introductionmentioning