2013
DOI: 10.1016/j.bmc.2013.04.029
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis of new 18F-radiolabeled silicon-based nitroimidazole compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 31 publications
(74 reference statements)
0
15
0
Order By: Relevance
“…Sodium azide, ethylene diaminetetraacetic acid disodium salt (EDTA·2Na) and sodium iodide (NaI) were purchased from Nakarai Tesque. α‐Chloro‐ω‐propargyl‐di(ethylene glycol), α‐chloro‐ω‐propargyl‐tri(ethylene glycol), GAP, and the model polymer of glycidyl 4‐benzyl‐1,2,3‐triazole polymer (GTP‐C‐Ph) were synthesized according to the literature …”
Section: Methodsmentioning
confidence: 99%
“…Sodium azide, ethylene diaminetetraacetic acid disodium salt (EDTA·2Na) and sodium iodide (NaI) were purchased from Nakarai Tesque. α‐Chloro‐ω‐propargyl‐di(ethylene glycol), α‐chloro‐ω‐propargyl‐tri(ethylene glycol), GAP, and the model polymer of glycidyl 4‐benzyl‐1,2,3‐triazole polymer (GTP‐C‐Ph) were synthesized according to the literature …”
Section: Methodsmentioning
confidence: 99%
“…An initial study by Bohn et al and a follow-up investigation by Joyard et al demonstrated the synthesis, radiolabeling, and in vivo evaluation of silicon-based analogues of [ 18 F]FMISO, an established tracer for detection of hypoxia [62, 63]. In spite of the well-known steric requirements of the silicon atom, the authors described a series of alkyl substituted [ 18 F]SiFA-FMISO analogues which resulted in insufficient hydrolytic stability both in vitro and in vivo (Table 3; Entries 1 and 2).…”
Section: Small Moleculesmentioning
confidence: 99%
“…2,3 Due to these features, identification and quantitative assessment of tissue hypoxia is a significant factor for optimal therapy outcome. 4 Diverse invasive and non-invasive methods using various modalities are available to measure hypoxia in tumors. 5 Despite many invasive techniques available to assess tissue hypoxia, there are some limitations such as technical complexity, erratic results and impossibility of repetitive measurements.…”
Section: Introductionmentioning
confidence: 99%
“…8 High resolution images of PET are obtained by 18 F that has ideal physical properties such as a half-life of 110 min and a low-energy positron of 640 keV. 4 Nitroimidazole is generally employed and studied as an exogenous marker for tumor hypoxia, due to its unique property in hypoxic environments related to the reduction of its nitro group. [9][10][11][12][13] Reactive intermediates that accumulate in hypoxic tissues through binding to cellular constituents are generated by a reversible reduction step in normoxic cells but not hypoxic cells.…”
Section: Introductionmentioning
confidence: 99%