2020
DOI: 10.1007/s11094-020-02140-y
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis of a Disulfuram Inclusion Complex with Hydroxypropyl-β-Cyclodextrin and Its Effect on Cataract Development in Rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 8 publications
2
10
0
Order By: Relevance
“…As shown in Figure 4 a,b, DS powder has two sharp endothermic peaks at 74.2 °C and 208.9 °C, whilst no endothermic sharp peaks were detected in any of the pure CDs nor inclusion complexes, proving an efficient inclusion of the drug. Moreover, the peak detected at about 74.2 °C might correspond to the melting point indicating its crystalline state, whereas the peak detected at about 208.9 °C corresponds to its thermal degradation [ 24 , 28 ]. It was also observed in Figure 4 that the freeze-dried formulations (HP20 and SBE20) demonstrated similar profiles to that of raw CDs.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As shown in Figure 4 a,b, DS powder has two sharp endothermic peaks at 74.2 °C and 208.9 °C, whilst no endothermic sharp peaks were detected in any of the pure CDs nor inclusion complexes, proving an efficient inclusion of the drug. Moreover, the peak detected at about 74.2 °C might correspond to the melting point indicating its crystalline state, whereas the peak detected at about 208.9 °C corresponds to its thermal degradation [ 24 , 28 ]. It was also observed in Figure 4 that the freeze-dried formulations (HP20 and SBE20) demonstrated similar profiles to that of raw CDs.…”
Section: Resultsmentioning
confidence: 99%
“…The use of CD inclusion complexes to enhance the solubility of DS is reported in the literature for the treatment of other diseases such as cancer [ 23 , 24 ]. However, only one type of β-cyclodextrin was used at high concentrations, and no phase solubility studies were performed.…”
Section: Introductionmentioning
confidence: 99%
“…The thermogram for disulfiram show characteristic endotherms at 74 °C and 190–250 °C corresponding to melting and degradation events, respectively [ 46 ]. The thermograms for blank and loaded nanoparticles prepared by both methods were almost identical ( Figure 4 ), with a characteristic endotherm for the glass transition temperature for PLGA nanoparticles shown at 55 °C [ 47 ].…”
Section: Resultsmentioning
confidence: 99%
“…The sample was placed in an aluminum sample holder and scanned over the range between 4 to 80 • and position 2 Theta (θ) with increments of 0.008 • at a rate of 3 • /min at an ambient temperature. The raw data is converted into the graphical form using Origin Pro ® 2021 software (OriginLab Corporation, Northampton, MA, USA) [50]. The percentage crystallinity index (% CI) was determined using Equation (4).…”
Section: Crystallinity Of Powdermentioning
confidence: 99%
“…An average of 16 scans per sample was recorded. Spectra were plotted and analyzed using Origin Pro ® 2021 software (OriginLab Corporation, Northampton, MA, USA) [50].…”
Section: Ftir Analysismentioning
confidence: 99%