2020
DOI: 10.1007/s13204-020-01407-w
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis from aqueous solutions and optical properties of Ag–In–S quantum dots

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
35
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(42 citation statements)
references
References 57 publications
7
35
0
Order By: Relevance
“…1a shows the optical absorption spectra of size fractioned colloidal AgInS2 QD solutions. Similar to earlier studies of Ag-In-S QDs [10,13,19], a noticeable blue shift of the absorption edge is observed with increasing fraction number as evidence for the NC size decrease. While for extensively studied II-VI QDs, for which (if the average QD size is smaller than the exciton Bohr radius) one can observe distinct size-dependent maxima in the optical absorption spectra and determine, from their spectral positions, the average QD size using the effective mass approximation [22], here we did not observe any confinement-related maxima.…”
Section: Resultssupporting
confidence: 88%
See 2 more Smart Citations
“…1a shows the optical absorption spectra of size fractioned colloidal AgInS2 QD solutions. Similar to earlier studies of Ag-In-S QDs [10,13,19], a noticeable blue shift of the absorption edge is observed with increasing fraction number as evidence for the NC size decrease. While for extensively studied II-VI QDs, for which (if the average QD size is smaller than the exciton Bohr radius) one can observe distinct size-dependent maxima in the optical absorption spectra and determine, from their spectral positions, the average QD size using the effective mass approximation [22], here we did not observe any confinement-related maxima.…”
Section: Resultssupporting
confidence: 88%
“…While for extensively studied II-VI QDs, for which (if the average QD size is smaller than the exciton Bohr radius) one can observe distinct size-dependent maxima in the optical absorption spectra and determine, from their spectral positions, the average QD size using the effective mass approximation [22], here we did not observe any confinement-related maxima. This fact is well known for Ag-In-S QDs and can be explained by smearing the maxima due to the strong Urbach tail absorption by defect states [10,13,19].…”
Section: Resultsmentioning
confidence: 67%
See 1 more Smart Citation
“… 25 The other example to the pure PEI (10 kDa)-coated AIS QDs had a small hydrodynamic size and 32% QY but used a pressure cooker (120 °C) and did not report any long-term colloidal or luminescence stability. 22 Both had maximum emission below 600 nm. These examples clearly indicate the advantage of using a mixed coating and its utility in tuning size emission and imparting strong emission in an RT reaction.…”
Section: Resultsmentioning
confidence: 98%
“…These E g and Urbach energies agree with the values reported in the literature for the different anionic AIS QDs. 22 , 64 …”
Section: Resultsmentioning
confidence: 99%