2019
DOI: 10.1039/c8ra09833f
|View full text |Cite|
|
Sign up to set email alerts
|

Synthesis, characterization and electrochemical analysis of cysteine modified polymers for corrosion inhibition of mild steel in aqueous 1 M HCl

Abstract: Mild steel framework embedded in corrosion inhibiting structural motifs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 28 publications
(18 citation statements)
references
References 63 publications
(63 reference statements)
1
17
0
Order By: Relevance
“…Several research studies reported that if the variation of E corr value in the presence of corrosion inhibitor is >85 mV, then the corrosion inhibitor is considered to be a cathodic or anodic type inhibitor. On the other hand, if the variation of E corr value in the presence of corrosion inhibitor is <85 mV, then the corrosion inhibitor would be considered a mixed type inhibitor [18,40,51]. In this study, the maximum shift in E corr was found to be 36 mV towards the anodic direction, indicating that the corrosion inhibitor cannot solely be classified as anodic type inhibitor but can be recognized as a mixed type inhibitor.…”
Section: Potentiodynamic Polarization Studymentioning
confidence: 63%
See 4 more Smart Citations
“…Several research studies reported that if the variation of E corr value in the presence of corrosion inhibitor is >85 mV, then the corrosion inhibitor is considered to be a cathodic or anodic type inhibitor. On the other hand, if the variation of E corr value in the presence of corrosion inhibitor is <85 mV, then the corrosion inhibitor would be considered a mixed type inhibitor [18,40,51]. In this study, the maximum shift in E corr was found to be 36 mV towards the anodic direction, indicating that the corrosion inhibitor cannot solely be classified as anodic type inhibitor but can be recognized as a mixed type inhibitor.…”
Section: Potentiodynamic Polarization Studymentioning
confidence: 63%
“…The IR spectra of polymers 5-7 were recorded by FT-IR in the frequency range 400-4000 cm −1 (Figure 1). The FT-IR spectra of polymers 5-7 showed that there is a strong absorption peak present around 3425 cm −1 due to the hydrogen bonded N-H group [40]. The symmetric and antisymmetric absorption peaks appearing at~1455 and~1458 cm −1 , respectively, suggested COO − motifs in the polymers 5 and 7 [36].…”
Section: Polymers' Syntheses and Characterizationsmentioning
confidence: 96%
See 3 more Smart Citations