2023
DOI: 10.1021/acschemneuro.3c00025
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and In Vitro and In Vivo Evaluation of 18F-Labeled Positron Emission Tomography Tracers for Imaging Aβ Plaques

Abstract: Accurate quantification of amyloid beta (Aβ) plaques is an important indicator for Alzheimer’s disease diagnosis and treatment. For this purpose, new highly sensitive Aβ tracers were designed by regulating the position and number of nitrogen atoms. A series of derivatives of florbetapir (AV45) containing different numbers and positions of N atoms were synthesized and evaluated for in vitro affinity and in vivo biodistribution. Preliminary study results showed that [18F]­BIBD-124 and [18F]­BIBD-127 had better c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 65 publications
0
6
0
Order By: Relevance
“…Nude mice (female, weight 12–16 g) bearing MCF-7 and 22Rv1 xenografts and intracranial U87MG and C6 tumors were purchased from Guangdong GemPharmatech Co., Ltd. Data were recorded on a Madiclab PSA146 PET/CT/FMT instrument. Dynamic microPET-CT imaging studies were conducted with [ 18 F]­8a , [ 18 F]­8d , [ 18 F]­8g , [ 18 F]­8j , [ 18 F]­FTT, or [ 18 F]­BIBD-300, similar to that reported previously . A total of 8–11 MBq of activity was injected intravenously via the lateral tail vein.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Nude mice (female, weight 12–16 g) bearing MCF-7 and 22Rv1 xenografts and intracranial U87MG and C6 tumors were purchased from Guangdong GemPharmatech Co., Ltd. Data were recorded on a Madiclab PSA146 PET/CT/FMT instrument. Dynamic microPET-CT imaging studies were conducted with [ 18 F]­8a , [ 18 F]­8d , [ 18 F]­8g , [ 18 F]­8j , [ 18 F]­FTT, or [ 18 F]­BIBD-300, similar to that reported previously . A total of 8–11 MBq of activity was injected intravenously via the lateral tail vein.…”
Section: Methodsmentioning
confidence: 99%
“…[ 18 F]FTT, or [18 F]BIBD-300, similar to that reported previously 28. A total of 8−11 MBq of activity was injected intravenously via the lateral tail vein.…”
mentioning
confidence: 99%
“…Nude mice (female, weight 12–16 g) bearing U87MG xenografts and intracranial tumors were purchased from Guangdong GemPharmatech Co., Ltd. Data were recorded on a Madiclab PSA146 PET/CT/FMT instrument. Dynamic microPET-CT imaging studies were conducted with [ 18 F]­1a , [ 18 F]­1b , or [ 68 Ga]­FAPI04, similar to that reported previously . A total of 8–11 MBq of activity was injected intravenously via the lateral tail vein.…”
Section: Methodsmentioning
confidence: 99%
“…Dynamic microPET-CT imaging studies were conducted with [ 18 F]1a, [ 18 F]1b, or [ 68 Ga]FAPI04, similar to that reported previously. 29 imaging was collected at 2 and 4 h postinjection. All animals were sedated with isoflurane anesthesia (2−3%, 1 L/min oxygen) and then placed on a heating pad to maintain body temperature throughout the procedure.…”
mentioning
confidence: 99%
“…Data were recorded on a Madiclab PSA146 PET/CT/FMT instrument. Dynamic small animal PET-CT imaging studies were conducted with (2S,4S)-4-[ 18 F]­FEBGln similar to that reported previously. , All scans were performed on a dedicated animal PET scanner. Nude mice with MCF-7, NCI-h1975, 22Rv1, or U87MG tumors were used for the imaging studies.…”
Section: Methodsmentioning
confidence: 99%