2021
DOI: 10.1111/1750-3841.15896
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and characterization of tracers and development of a fluorescence polarization immunoassay for amantadine with high sensitivity in chicken

Abstract: Fluorescence polarization immunoassay (FPIA) is a homogeneous and rapid analytical method that is suitable for high-throughput screening of large numbers of samples. However, FPIA typically suffers from lower sensitivity than the well-established enzyme-linked immunosorbent assay (ELISA), limiting its wide application as an analytical tool that can be run with trace levels of an analyte. Herein, a highly sensitive FPIA for detecting amantadine (AMD) in chicken is described. To achieve high sensitivity, nine ch… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 37 publications
0
6
0
Order By: Relevance
“…In this study, ERY-CMO was obtained using ERY modified by CMO at the C9 position and introducing a reactive carbonyl group as previously described [ 28 ]. Tracer synthesis is important for the establishment of a highly sensitive and specific FPIA, once the antibody is prepared [ 29 , 31 ]. Therefore, to achieve highly sensitive detection of ERY, five new tracers including ERY-CMO-4′-AMF, ERM-FITC, ERM-DTAF, ERM-SRSC, and ERM-AF647 were designed using two haptens and five fluoresceins ( Figure 2 ).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In this study, ERY-CMO was obtained using ERY modified by CMO at the C9 position and introducing a reactive carbonyl group as previously described [ 28 ]. Tracer synthesis is important for the establishment of a highly sensitive and specific FPIA, once the antibody is prepared [ 29 , 31 ]. Therefore, to achieve highly sensitive detection of ERY, five new tracers including ERY-CMO-4′-AMF, ERM-FITC, ERM-DTAF, ERM-SRSC, and ERM-AF647 were designed using two haptens and five fluoresceins ( Figure 2 ).…”
Section: Resultsmentioning
confidence: 99%
“…In FPIA, limited tracer and antibody concentrations are considered to achieve the desired performance [ 29 ]. In addition, the dyes applied in this study were pH-sensitive reagents, and the combination between the mAb and tracers could be significantly affected by buffer pH [ 31 , 32 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Different antibody–tracer pairs may have a crucial impact on the sensitivity and accuracy in the development of FPIA [ 29 , 35 ]. To obtain the best antibody–tracer pair, we calculated the antibody titers of each mAb–tracer pair according to the antibody dilution curves ( Table 1 and Figure S2 ).…”
Section: Resultsmentioning
confidence: 99%
“…For more than a decade, our group has reported many FPIA methods to detect hazardous compounds, such as aflatoxins, zearalenone, sulfamethazine, orbifloxacin, and amantadine. [ 17 , 25 , 27 , 28 , 29 ]. However, to the best of our knowledge, no DWFPIA method has been reported for the simultaneous detection of SAs and ASGs in foodstuffs.…”
Section: Introductionmentioning
confidence: 99%