2009
DOI: 10.1016/j.jconrel.2009.04.026
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and characterization of reactive poloxamer 407s for biomedical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
38
0
3

Year Published

2010
2010
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 70 publications
(41 citation statements)
references
References 28 publications
0
38
0
3
Order By: Relevance
“…This is consistent with previous studies demonstrating measurable but modest effects of end group modification of reverse thermal gelation behavior of other amphiphilic polymers. [43] A second limitation is that the rheometer used lacked a humidified chamber and although most tests were relatively brief, the possibility of some evaporation cannot be eliminated and this may have contributed to the different gel point values measured for the 75/25 and 50/50 groups by rheology and tube inversion.…”
Section: Discussionmentioning
confidence: 99%
“…This is consistent with previous studies demonstrating measurable but modest effects of end group modification of reverse thermal gelation behavior of other amphiphilic polymers. [43] A second limitation is that the rheometer used lacked a humidified chamber and although most tests were relatively brief, the possibility of some evaporation cannot be eliminated and this may have contributed to the different gel point values measured for the 75/25 and 50/50 groups by rheology and tube inversion.…”
Section: Discussionmentioning
confidence: 99%
“…81 Despite this, the biostability properties and the too rapid degradation in aqueous environment of this hydrogels still limit their use as cellularized scaffolds in vivo. 81,129 …”
Section: Hydrogels: Suitable Micro-environments For Btementioning
confidence: 99%
“…Despite the attractive properties of P407 as a thermogelling material, there are several drawbacks for P407 hydrogels such as, weak mechanical strength due to P407's shear thinning character, rapid dissolution, and weak mucoadhesion, which has made it unfavorable for topical applications, or other areas where the gel may be affected by shear . For instance, a 20% w/w P407 formulation containing acyclovir was administered intravaginally to mice and after 3 h only half of the acyclovir administered was detected, and none was found after 6 h .…”
Section: Poloxamer 407 As a Thermogelling Materialsmentioning
confidence: 99%
“…As such, it has been widely investigated for various biomedical applications, including drug delivery, wound dressings, and cell culture . However, there are significant drawbacks for thermogelling poloxamer 407 solutions including insufficient gel strength for some applications, weak mucoadhesiveness, and rapid dissolution of the gels formed which has limited its performance, particularly in drug delivery systems . To improve gel strength, researchers have investigated blending poloxamer with other hydrophilic polymers or nanoparticles as well as chemically modifying the structure of P407.…”
Section: Introductionmentioning
confidence: 99%