2012
DOI: 10.1016/j.ijbiomac.2012.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and characterization of novel nano-chitosan Schiff base and use of lead (II) sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 47 publications
(11 citation statements)
references
References 29 publications
0
11
0
Order By: Relevance
“…Since the beginning of this century, the interest in materials at the nanoscale has been steadily increasing based on the fact that the quantum size of nanomaterials triggers new physical, electronic, and magnetic properties. Thus the synthesis and characterization of nanostructures with different particle sizes and morphologies are important both from the viewpoint of basic science as well as for technological applications . A few studies have been done on the synthesis of nanoparticles of Schiff base complexes and their application .…”
Section: Introductionmentioning
confidence: 99%
“…Since the beginning of this century, the interest in materials at the nanoscale has been steadily increasing based on the fact that the quantum size of nanomaterials triggers new physical, electronic, and magnetic properties. Thus the synthesis and characterization of nanostructures with different particle sizes and morphologies are important both from the viewpoint of basic science as well as for technological applications . A few studies have been done on the synthesis of nanoparticles of Schiff base complexes and their application .…”
Section: Introductionmentioning
confidence: 99%
“…The emergence of a peak at 1659 cm −1 indicates the C O in amide group [28]. The biosorbent showed a shift in the amino peak from 1595 cm −1 to 1591 cm −1 [29]. The appearance of peak at 1627 cm −1 is indicative of C N imine group of the glutaraldehyde crosslinked chitosan.…”
Section: Ftir and Sem-edax Analysismentioning
confidence: 96%
“…At pH higher than 5.0, the decrease in the anodic peak current may be due to the hydrolysis of cations. 31…”
Section: 1 Effect Of Supporting Electrolyte and Phmentioning
confidence: 99%
“…(A.2), respectively, where δ is the standard deviation (8 replicate determinations of the blank signals) of blank and s is the slope of calibration curve. 31 (1)…”
Section: Analytical Characteristicsmentioning
confidence: 99%