2017
DOI: 10.1016/j.cej.2016.11.137
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and characterization of new nanocomposite CTAB-PTA@CS as an efficient heterogeneous catalyst for oxidative desulphurization of gasoline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
39
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 79 publications
(40 citation statements)
references
References 35 publications
1
39
0
Order By: Relevance
“…04–0835). The diffraction pattern of pure CTS that is shown in Figure (c) has a sharp peak at 19.8° which demonstrates the semi‐crystalline nature of polymer . The Fe 2 W 18 Fe 4 @NiO@CTS nanocatalyst was exhibited similar reflections to the pattern of NiO and CTS support and the peaks of Fe 2 W 18 Fe 4 did not observe clearly (Figure (d)).…”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…04–0835). The diffraction pattern of pure CTS that is shown in Figure (c) has a sharp peak at 19.8° which demonstrates the semi‐crystalline nature of polymer . The Fe 2 W 18 Fe 4 @NiO@CTS nanocatalyst was exhibited similar reflections to the pattern of NiO and CTS support and the peaks of Fe 2 W 18 Fe 4 did not observe clearly (Figure (d)).…”
Section: Resultsmentioning
confidence: 94%
“…The removal efficiencies of MTCs from the model fuels at 35 °C rapidly were increased from 35% in the 10 min of reaction up to 95% as the stirring time increased to 60 min. Thus, reaction temperature and time were set to 30 °C and 60 min, respectively, as optimum conditions of ODS systems …”
Section: Resultsmentioning
confidence: 99%
“…In Table , the Arrhenius plots and the calculated E a values for the oxidation of DBT, BT, and Th were 44.364, 45.419, and 51.560 kJ mol −1 , respectively (Figure ) that the values were compared with that of other ODS system reported in the previous literature .…”
Section: Resultsmentioning
confidence: 87%
“…As shown in Figure 3, the Bragg peaks of PMA within 10-508 corresponding to the characteristic diffraction peaks of Keggin-type structures, attributed to (001), (110), (140), and (014) planes [24]. The CS with semicrystalline nature exhibited refraction at 19.98 ( Figure 3c) [22]. From the spectra of IMID-PMA@CS, the appeared broad amorphous peaks in nanocomposite pattern suggested the fine dispersion of IMID@PMA units on the CS surface (Figure 3d).…”
Section: X-ray Diffraction (Xrd) Analysismentioning
confidence: 95%
See 1 more Smart Citation