2009
DOI: 10.1002/pen.21619
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and antibiofouling properties of novel crosslinkable terpolymers containing semifluoroalkyl substituted aromatic side chains

Abstract: Synthesis, contact angle analysis, surface properties and biofouling characteristics of novel crosslinkable terpolymers with semifluoroalkyl substituted aromatic side chains have been described. These polymers are targeted for use as coatings to prevent marine biofouling. The marine antifouling properties of these materials were evaluated by laboratory assays employing the fouling diatom Nitzschia and ubiquitous Staphylococcus aureusi. Results indicated that the experimental coatings exhibited better antibiofo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…NMR spectra were recorded at ambient temperature on a Bruker AV400 spectrometer at 400.0 and 377.0 MHz for 1 H and 19 F nuclei, respectively. Tetramethylsilane (TMS) was applied as the internal chemical shi reference for 1 H NMR spectra and CFCl 3 as an external standard for 19 F NMR spectra, downeld shis are designated as positive. Fourier transform infrared (FT-IR) spectra were recorded on a FT-IR spectrometer (Avatar 380) using KBr crystals in the infrared region of 4000-400 cm À1 .…”
Section: Measurementsmentioning
confidence: 99%
See 4 more Smart Citations
“…NMR spectra were recorded at ambient temperature on a Bruker AV400 spectrometer at 400.0 and 377.0 MHz for 1 H and 19 F nuclei, respectively. Tetramethylsilane (TMS) was applied as the internal chemical shi reference for 1 H NMR spectra and CFCl 3 as an external standard for 19 F NMR spectra, downeld shis are designated as positive. Fourier transform infrared (FT-IR) spectra were recorded on a FT-IR spectrometer (Avatar 380) using KBr crystals in the infrared region of 4000-400 cm À1 .…”
Section: Measurementsmentioning
confidence: 99%
“…18 (2.16 g, 67% yield), 1 H NMR (400 MHz, CDCl 3 ) d (ppm): 6.66 (dd, J ¼ 18.0, 11.9 Hz, 1H), 6.08 (d, J ¼ 18.0 Hz, 1H), 5.69 (d, J ¼ 11.9 Hz, 1H), 4.53 (t, J ¼ 6.7 Hz, 2H), 2.79-2.60 (m, 2H). 19 F NMR (377 MHz, CDCl 3 ) d (ppm): À80.8 (t, J ¼ 10.3 Hz, 3F), À113.4 (dt, J ¼ 33.5, 18.5 Hz, 2F), À121.9 (s, 2F), À122.9 (s, 2F), À123.5 (s, 2F), À126.0 to À126.4 (m, 2F), À144.4 (dd, J ¼ 22.1, 10.0 Hz, 2F), À158.1 (dd, J ¼ 21. 8, 9.7 19 F NMR (377 MHz, CDCl 3 ) d (ppm): À80.2 to À83.3 (m, 13F), À130.0 to À130.6 (m, 2F), À134.2 to À136.2 (m, 1F), À144.0 to À144.6 (m, 2F), À145.1 to À145.9 (m, 1F), À157.7 to À160.4 (m, 2F General procedure for copolymerization.…”
Section: Synthesismentioning
confidence: 99%
See 3 more Smart Citations