2023
DOI: 10.1016/j.jhazmat.2023.131591
|View full text |Cite
|
Sign up to set email alerts
|

Synergy of S-vacancy and heterostructure in BiOCl/Bi2S3−x boosting room-temperature NO2 sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 41 publications
(14 citation statements)
references
References 74 publications
0
14
0
Order By: Relevance
“…The gas-sensing mechanism of the three-component heterojunction Co 3 O 4 –CoS 2 @MoS 2 -2 composite is primarily attributed to the variation in resistance when exposed to a NO 2 atmosphere. 40,41 Molybdenum disulfide nanosheets have high catalytic oxidation performance and form a heterostructure with Co 3 O 4 to speed up carrier transport. At the same time, the S atom in CoS 2 has a large capacity to hold electrons, which further promotes efficient carrier transport.…”
Section: Resultsmentioning
confidence: 99%
“…The gas-sensing mechanism of the three-component heterojunction Co 3 O 4 –CoS 2 @MoS 2 -2 composite is primarily attributed to the variation in resistance when exposed to a NO 2 atmosphere. 40,41 Molybdenum disulfide nanosheets have high catalytic oxidation performance and form a heterostructure with Co 3 O 4 to speed up carrier transport. At the same time, the S atom in CoS 2 has a large capacity to hold electrons, which further promotes efficient carrier transport.…”
Section: Resultsmentioning
confidence: 99%
“…The gas-sensing properties of the sensors were measured in a homemade 4 L test box with a mixing fan as in our previous work. 50 The resistance of sensors was monitored using an electrochemical workstation (CHI660E, CH Instruments). During the test, the concentration of the target gas was controlled by the amount of gas injected into the testing chamber.…”
Section: Methodsmentioning
confidence: 99%
“…According to OSHA (Occupational Safety and Health Administration) of the United States Department of Labor, the level of NO 2 should be less than 5 ppm for 8 h exposure. , In 2010, the United States Environmental Protection Agency (EPA) also set the ambient air quality standards for nitrogen dioxide (NO 2 ) to be a 1-h standard at a level of 100 ppb and a long-term exposure standard at 53 ppb. , To effectively detect low concentrations of NO 2 gas, related studies have sprung up in recent years. There are many metal-oxide sensors to detect NO 2 . However, to monitor NO 2 in our daily life, low-cost and reliable NO 2 gas sensors are still needed.…”
Section: Introductionmentioning
confidence: 99%