2021
DOI: 10.1038/s41467-021-27164-0
|View full text |Cite
|
Sign up to set email alerts
|

Synergistic insights into human health from aptamer- and antibody-based proteomic profiling

Abstract: Affinity-based proteomics has enabled scalable quantification of thousands of protein targets in blood enhancing biomarker discovery, understanding of disease mechanisms, and genetic evaluation of drug targets in humans through protein quantitative trait loci (pQTLs). Here, we integrate two partly complementary techniques—the aptamer-based SomaScan® v4 assay and the antibody-based Olink assays—to systematically assess phenotypic consequences of hundreds of pQTLs discovered for 871 protein targets across both p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

13
142
2

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 110 publications
(157 citation statements)
references
References 62 publications
(94 reference statements)
13
142
2
Order By: Relevance
“…Five matching pairs of assays have a strong negative correlation (<-0.18) with those targeting PILRA having the strongest negative correlation (-0.32). As previously described, PILRA has a cis pQTL with opposite directions of effect on the Olink Explore and SomaScan v4 platforms 8 , a result that we also observe in our data (Arg78Gly; MAF=32%; Olink Explore p =7.9×10 -7823 , effect=-1.01 SD and SomaScan v4 p =1.0×10 -9045 , effect=1.31). We observe that the range of levels for matching assays was similar on the two platforms (IQR correlation 0.51, p =8.2×10 -81 ).…”
Section: Resultssupporting
confidence: 90%
See 4 more Smart Citations
“…Five matching pairs of assays have a strong negative correlation (<-0.18) with those targeting PILRA having the strongest negative correlation (-0.32). As previously described, PILRA has a cis pQTL with opposite directions of effect on the Olink Explore and SomaScan v4 platforms 8 , a result that we also observe in our data (Arg78Gly; MAF=32%; Olink Explore p =7.9×10 -7823 , effect=-1.01 SD and SomaScan v4 p =1.0×10 -9045 , effect=1.31). We observe that the range of levels for matching assays was similar on the two platforms (IQR correlation 0.51, p =8.2×10 -81 ).…”
Section: Resultssupporting
confidence: 90%
“…Direct comparison of the levels measured with matching assays on the two platforms gave a median correlation of 0.46, with a bimodal distribution with modes around 0 and 0.7. Similar correlation has been reported between proteins measured using Olink Target and SomaScan v4 8 , highlighting a clear difference between the platforms.…”
Section: Discussionsupporting
confidence: 82%
See 3 more Smart Citations