Synergistic inhibition of carbon steel corrosion in seawater by cerium chloride and sodium gluconate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 73 publications
(20 citation statements)
references
References 47 publications
(55 reference statements)
0
18
0
Order By: Relevance
“…The metallic ions of these salts should use alone and concentration above 250 ppm above to give a good inhibition efficiency. [ 35,36 ] A methodical path is needed to analyze the protection properties of cerium ion as a green corrosion inhibitor and hydrogen evolution of CS in acidic environment, to signify that cerium ion acts as cathodic inhibitor and suppresses hydrogen ion reduction on CS. [ 35,37 ] The corrosion process of CS in acidic medium is an electrochemical in nature which takes a part in electron exchange between cathodic and anodic sites.…”
Section: Application Of Various Corrosion Inhibitors On Cs Substratementioning
confidence: 99%
“…The metallic ions of these salts should use alone and concentration above 250 ppm above to give a good inhibition efficiency. [ 35,36 ] A methodical path is needed to analyze the protection properties of cerium ion as a green corrosion inhibitor and hydrogen evolution of CS in acidic environment, to signify that cerium ion acts as cathodic inhibitor and suppresses hydrogen ion reduction on CS. [ 35,37 ] The corrosion process of CS in acidic medium is an electrochemical in nature which takes a part in electron exchange between cathodic and anodic sites.…”
Section: Application Of Various Corrosion Inhibitors On Cs Substratementioning
confidence: 99%
“…Subsequent to cleaning, the electrodes were rinsed with acetone and deionized water and nally dried in warm air. 20,21 The working electrode was rst immersed into the test solution for 2000 seconds to establish steady-state open-circuit potential.…”
Section: Electrochemical Techniquesmentioning
confidence: 99%
“…Mild steel is one of the main construction materials, which is extensively utilized in many industrial applications and devices. Its tendency to undergo indentation and corrosion in aqueous solutions especially in acidic medium is the major disadvantage despite its low cost and excellent mechanistic characteristics [1][2][3]. Te acidic medium H 2 SO 4 or HCl is used in manufacturing processes such as cleaning, pickling, and descaling as well as in oil drilling [4].…”
Section: Introductionmentioning