Synchrotron-based micro computed tomography investigation of the implant-abutment fatigue-induced microgap changes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 33 publications
1
10
0
Order By: Relevance
“…As a consequence, the risk of screw loosening and of potential mechanical complications may increase. According to the literature, the microgap between the implant and the abutment has a large impact on implant treatment success [ 4 , 20 , 51 , 57 , 58 , 59 ]. However, it should be mentioned that microgaps of 10 µm or less exert no harmful effects, either to hard or to soft tissues [ 54 , 55 , 56 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…As a consequence, the risk of screw loosening and of potential mechanical complications may increase. According to the literature, the microgap between the implant and the abutment has a large impact on implant treatment success [ 4 , 20 , 51 , 57 , 58 , 59 ]. However, it should be mentioned that microgaps of 10 µm or less exert no harmful effects, either to hard or to soft tissues [ 54 , 55 , 56 ].…”
Section: Discussionmentioning
confidence: 99%
“…It is worth emphasizing that due to the shadow effect, measurement error might occur [ 21 ]. In the MCT study, the Morse cone exhibited similar microgap values for the butt-joint connection (0.26–0.47 µm) [ 58 ].…”
Section: Discussionmentioning
confidence: 99%
“…Screw loosening of the conical connection group during the chewing simulation might be the result of the abutment "sinking" into the implant because of the chewing load. Studies have reported a vertical displacement of the abutment in relation to the implant [39,42,43]. This vertical displacement might cause slippage between the threads of the screw and the threads of the implant, resulting in the loss of the preload and screw loosening.…”
Section: Discussionmentioning
confidence: 99%
“…Bagegni et al 65 evaluated the impact of dynamic loading on the micro gap of the implant-abutment connection when various superstructure heights are selected. 48 dental implants divided two groups (butt-joint and internalchronic connection) each containing 24 implants, and also according to the height of the superstructure they were further divided into the subgroup.…”
Section: Evaluation Of Changes In the Implant-abutment Connectionmentioning
confidence: 99%