2022
DOI: 10.1016/j.envint.2022.107453
|View full text |Cite
|
Sign up to set email alerts
|

Synchronous removal of pharmaceutical contaminants and inactivation of pathogenic microorganisms in real hospital wastewater by electro-peroxone process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 56 publications
0
7
0
Order By: Relevance
“…Furthermore, 5,5-dimethyl-1-pyrroline- N -oxide (DMPO) and 2,2,6,6-tetramethyl-4-piperidinyloxy (TEMP) were selected as trapping agents for radicals ( • OH and SO 4 •– ) and 1 O 2 , respectively. Signals of • OH and SO 4 •– in all Fe–N x C 4– x /PMS systems were negligible (Figure S27), confirming the absence of radicals. When TEMP was added, an enhanced triplet EPR signal ascribed to 1 O 2 emerged in all Fe–N x C 4– x /PMS systems but was low-intensity in control systems (Figure g,h), demonstrating the generation of 1 O 2 .…”
Section: Resultsmentioning
confidence: 79%
“…Furthermore, 5,5-dimethyl-1-pyrroline- N -oxide (DMPO) and 2,2,6,6-tetramethyl-4-piperidinyloxy (TEMP) were selected as trapping agents for radicals ( • OH and SO 4 •– ) and 1 O 2 , respectively. Signals of • OH and SO 4 •– in all Fe–N x C 4– x /PMS systems were negligible (Figure S27), confirming the absence of radicals. When TEMP was added, an enhanced triplet EPR signal ascribed to 1 O 2 emerged in all Fe–N x C 4– x /PMS systems but was low-intensity in control systems (Figure g,h), demonstrating the generation of 1 O 2 .…”
Section: Resultsmentioning
confidence: 79%
“…The TOC of the treated sewage water decreases from 27 mg/L to below 5 mg/L for all treatment techniques (Table 2). This reflects a direct correlation between reduction in SARS-CoV-2 RNA, PMMoV, and other microbes in the sewage water and reduction in total organic carbon load as all these viruses and bacteria contain organic carbons (Li et al, 2022; Yu et al, 2022). Also, the dissolved oxygen (DO) level of treated sewage water has increased from 5 mg/L to 15 mg/L, which is a good indicator of water quality.…”
Section: Resultsmentioning
confidence: 98%
“…There have been numerous techniques and couplings of electro-Fenton processes to enhance the utilization efficiency of electrical energy and improve reaction efficiency, including electro-persulfate, electro-peroxone, , electro-Fenton coupled with anodic oxidation, photo-electro-Fenton, electro-Fenton membrane, and electro-Fenton coupled with H* . Therein, by introducing external oxidants, the utilization efficiency of electrical energy and the efficiency of radical generation are enhanced in electro-persulfate (coupling electrochemistry with persulfate) and electro-peroxone (coupling 2e – ORR for H 2 O 2 with O 3 ) systems, thereby improving the removal efficiency of pollutants.…”
Section: Challenges Research Gaps and Perspectivesmentioning
confidence: 99%