Switching Surge of Shunt Reactor Caused by SF6 Circuit Breaker Operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1988
1988
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…The chopping current of the circuit breaker was detected to be between 0 and 30 A. As both the objects studied in this paper and in [19] are a SF 6 puffer circuit breaker, the chopping coefficient λ has the same range. Compared with the shunt reactor in [19], the voltage and capacity of the 66 kV, 20 MVA shunt reactor in this paper are much smaller, and the stray capacitance is much smaller.…”
Section: ) Breaker Modelmentioning
confidence: 74%
See 2 more Smart Citations
“…The chopping current of the circuit breaker was detected to be between 0 and 30 A. As both the objects studied in this paper and in [19] are a SF 6 puffer circuit breaker, the chopping coefficient λ has the same range. Compared with the shunt reactor in [19], the voltage and capacity of the 66 kV, 20 MVA shunt reactor in this paper are much smaller, and the stray capacitance is much smaller.…”
Section: ) Breaker Modelmentioning
confidence: 74%
“…As both the objects studied in this paper and in [19] are a SF 6 puffer circuit breaker, the chopping coefficient λ has the same range. Compared with the shunt reactor in [19], the voltage and capacity of the 66 kV, 20 MVA shunt reactor in this paper are much smaller, and the stray capacitance is much smaller. Therefore, the total capacitance C t is small, and the chopping current is 0-13 A in this paper.…”
Section: ) Breaker Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…If high-frequency arc extinction takes place, repeated cycles of re-ignition and arc extinction may occur, thus causing multiple re-ignitions; on the other hand, the voltage may increase gradually [1,2], causing an overvoltage that is dangerous for the insulation of the equipment.…”
Section: Re-ignition Phenomena Related To Reactor Current Interruptionmentioning
confidence: 99%
“…Transformer CT1 was intended to measure the total HF current; transformer CT2 was used to measure small signals around the zero points of the HF current, and hence a diode clipper was connected at the output [2]. Transformer CT1 was intended to measure the total HF current; transformer CT2 was used to measure small signals around the zero points of the HF current, and hence a diode clipper was connected at the output [2].…”
Section: Test Circuit and Measurement Of High-frequency Currentmentioning
confidence: 99%