2021
DOI: 10.3390/sym13061074
|View full text |Cite
|
Sign up to set email alerts
|

Switching Order after Failures in Symmetric Protective Electrical Circuits with Triple Modal Reservation

Abstract: This work is devoted to the research of new asymmetry effects in symmetric protective structures with triple modal reservation. We analyzed the structures with different cross-sectional locations of the reference conductor: in the center (unshielded structure), around (shielded structure), at the top and bottom (multilayer printed circuit board), and in the form of side polygons (double-sided printed circuit board). First, a preliminary quasi-static simulation was performed in the range of parameters. It was r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…Modal reservation (MR) of circuits [39,40] Complex reservation of UAV circuits at the level of components, boards, and cables ensures the survivability of the UAV using modal decomposition. A number of studies have been carried out directly on the hybridization of reservation and modal filtration into a single whole.…”
Section: Methods Of Hollow and Thin Passive Conductorsmentioning
confidence: 99%
“…Modal reservation (MR) of circuits [39,40] Complex reservation of UAV circuits at the level of components, boards, and cables ensures the survivability of the UAV using modal decomposition. A number of studies have been carried out directly on the hybridization of reservation and modal filtration into a single whole.…”
Section: Methods Of Hollow and Thin Passive Conductorsmentioning
confidence: 99%
“…Typical structures for implementing triple MR have been proposed: multiconductor transmission lines (MCTL). The order of switching after failures and the identification of the best configuration of parameters were investigated in [11].…”
Section: Introductionmentioning
confidence: 99%
“…Previously, the characteristics of protective circuits with a triple MR, represented as multiconductor transmission lines, were considered in [26]. The optimal switching order after failures in a multilayer structure with a triple MR was investigated in [27]. In [28], the efficiency of MR in the circuits of a spacecraft autonomous navigation system was evaluated.…”
Section: Introductionmentioning
confidence: 99%