2019
DOI: 10.1049/iet-pel.2018.6287
|View full text |Cite
|
Sign up to set email alerts
|

Switch fault diagnosis for boost DC–DC converters in photovoltaic MPPT systems by using high‐gain observers

Abstract: Open-and short-circuit faults (OSCFs) in boost dc-dc converters for photovoltaic (PV) maximum power point trackers (MPPTs) imply an inefficiency after fault is triggered, which affect the security and profitability of PV projects. Hence, fault detection and isolation (FDI) techniques have become an important issue for PV technology. In this study, a model-based FDI technique is proposed to boost dc-dc converters in PV MPPT systems. As is well-known, major issues of model-based FDI techniques have always been p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 17 publications
(16 reference statements)
0
2
0
Order By: Relevance
“…This endeavor was further expanded upon in [10] by integrating an extra measurement strategy reliant on a magnetic near-field probe. References [11] and [12] introduced model-based FDI approaches for diagnosing OCF and SCF in DC-DC boost converters.…”
Section: Fault Detection For Energy Systemsmentioning
confidence: 99%
“…This endeavor was further expanded upon in [10] by integrating an extra measurement strategy reliant on a magnetic near-field probe. References [11] and [12] introduced model-based FDI approaches for diagnosing OCF and SCF in DC-DC boost converters.…”
Section: Fault Detection For Energy Systemsmentioning
confidence: 99%
“…Few of them were reviewed here. Espinoza Trejo et al 20 have mitigated the faults through utilizing HGO as remaining generator. HGO stands for high‐gain observer (HGO).…”
Section: A Brief Review Of Recent Research Workmentioning
confidence: 99%