Current Topics in Contact Dermatitis 1989
DOI: 10.1007/978-3-642-74299-6_102
|View full text |Cite
|
Sign up to set email alerts
|

Swedish Multicenter Study with TRUE Test, Panel 2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1994
1994
2015
2015

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…The comparative multicentre studies with TRUE Test™ and Finn Chambers™ indicate proximity between limits of weak sensitization and irritancy with nickel sulfate, potassium dichromate, cobalt chloride, balsam of Peru (Myroxylon pereirae resin), fragrance mix, carba mix and thimerosal (19, 20). In addition, some allergens such as lanolin alcohol and cobalt chloride frequently produce doubtful and irrelevant reactions (20, 21, 67, 68).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The comparative multicentre studies with TRUE Test™ and Finn Chambers™ indicate proximity between limits of weak sensitization and irritancy with nickel sulfate, potassium dichromate, cobalt chloride, balsam of Peru (Myroxylon pereirae resin), fragrance mix, carba mix and thimerosal (19, 20). In addition, some allergens such as lanolin alcohol and cobalt chloride frequently produce doubtful and irrelevant reactions (20, 21, 67, 68).…”
Section: Discussionmentioning
confidence: 99%
“…This test has been pharmaceutically optimized concerning stability, solubility and bioavailability. The dose has been determined by dose-response studies and the amount per unit area standardized (14)(15)(16)(17)(18)(19)(20)(21)(22).…”
Section: Methodsmentioning
confidence: 99%
“…These results imply that the bioavailability of allergens in TRUE Test ® is similar to that in Finn Chambers ® , in spite of the lower concentrations. When TRUE Test ® panel II was introduced, the concentration of PTBP-FR was 0.040 mg/cm 2 (19,20). At the time of our study, the concentration of PTBP-FR had been increased to 0.050 mg/cm 2 .…”
Section: Discussionmentioning
confidence: 95%
“…The reliability and the reproducibility of the TT has previously been investigated and confirmed in Swedish multicenter studies [7,8], in European multicenter studies [9,10], and by groups of Authors until recently [11]. This study was performed to further evaluate the EPI, RPT and TT in clinical practice and to investigate the correspondence between these ready-to-apply methods and standard allergens tested with FC.…”
Section: Discussionmentioning
confidence: 96%