2016
DOI: 10.3928/01913913-20160509-03
|View full text |Cite
|
Sign up to set email alerts
|

Sutureless Lamellar Corneoscleral Patch Graft With Fibrin Sealant for Limbal Dermoid Removal

Abstract: A 2-year-old boy with Goldenhar syndrome had a limbal dermoid removed and covered with a lamellar corneoscleral patch graft that was attached with fibrin glue and no sutures. The graft healed and attached well. A sutureless technique is beneficial due to decreased scarring and chance of infection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…A fibrin-based adhesive was considered effective for sealing of conjunctival and skin grafts, LASIK flaps, and clear cornea incisions (Fig. 5Av) [118]. Likewise, the combined use of a fibrin glue and amniotic membrane transplantation was demonstrated as a safe and effective method for repairing corneas with perforations of around 2 mm [119].…”
Section: Fibrin and Fibrinogen-based Adhesivesmentioning
confidence: 99%
See 1 more Smart Citation
“…A fibrin-based adhesive was considered effective for sealing of conjunctival and skin grafts, LASIK flaps, and clear cornea incisions (Fig. 5Av) [118]. Likewise, the combined use of a fibrin glue and amniotic membrane transplantation was demonstrated as a safe and effective method for repairing corneas with perforations of around 2 mm [119].…”
Section: Fibrin and Fibrinogen-based Adhesivesmentioning
confidence: 99%
“…Adequate graft integration with no edema and minimum haze was observed. Adapted from Zhou et al[118] with permission from Healio, copyright 2016; (B) Albumin based adhesives: (i) The 3D structure of albumin; a globular protein abundantly present in animal serum, (ii) Mechanism of crosslinking and tissue adhesion of BioGlue ® , (iii) Schematic illustration of laser soldering using albumin-based solders. Adapted from Chao et al[126] with permission from Wiley, copyright 2003, (iv) Rat eyes glued with albumin soldering after corneal epithelium removal surgery, and (v) ex-vivo breaking strength measure on mouse skin soldered with albumin-based solder.…”
mentioning
confidence: 99%
“…Excision alone can cause scarring, corneal vascularization, pseudopterygium, and symblepharon. 23 , 24 , 25 , 26 , 27 Closing the defect with partial-thickness corneal grafts after resection reduces the development of these complications and creates a more cosmetically pleasing appearance. 26 , 27 AMT and conjunctivo-Tenonplasty was performed in the same session as dermoid excision in patient 1 and approximately 15 months after dermoid excision performed in another center in an attempt to close the area of scleral melting in patient 2.…”
Section: Discussionmentioning
confidence: 99%
“…23 , 24 , 25 , 26 , 27 Closing the defect with partial-thickness corneal grafts after resection reduces the development of these complications and creates a more cosmetically pleasing appearance. 26 , 27 AMT and conjunctivo-Tenonplasty was performed in the same session as dermoid excision in patient 1 and approximately 15 months after dermoid excision performed in another center in an attempt to close the area of scleral melting in patient 2. When adequate results could not be obtained, the patients were referred to our center and underwent donor corneal grafting ( Figure 1b ).…”
Section: Discussionmentioning
confidence: 99%
“…The graft successfully healed and adhered, demonstrating the advantages of a sutureless method, which reduces scarring and the risk of infection. [ 101 ] Bladder leakage is a common complication in existing glaucoma filtration surgeries. The application of autologous fibrin tissue glue has shown success in repairing leaks, providing a non‐surgical treatment option.…”
Section: Natural Biomaterials For Corneal Tissue Engineeringmentioning
confidence: 99%