2015
DOI: 10.1016/j.ijms.2014.07.023
|View full text |Cite
|
Sign up to set email alerts
|

Survival yield comparison between ESI and SAII: Mechanistic implications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
49
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(53 citation statements)
references
References 33 publications
4
49
0
Order By: Relevance
“…Understanding of ionization mechanisms is important to obtain the best available results for samples. As aforementioned, ionization mechanisms of SAII and zvPSI have been discussed previously . The main question is how charged droplets are created from initially neutral droplets without electric potential.…”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…Understanding of ionization mechanisms is important to obtain the best available results for samples. As aforementioned, ionization mechanisms of SAII and zvPSI have been discussed previously . The main question is how charged droplets are created from initially neutral droplets without electric potential.…”
Section: Resultsmentioning
confidence: 94%
“…The most attractive feature of SAII is no extra voltage, laser and nebulizing gas is required to obtain gas‐phase analyte ions, which simplifies or even eliminates the conventional ion sources attached to a mass spectrometer. Potential ionization mechanisms of SAII have been proposed by McEwen, Trimpin and co‐workers . According to these reports, thermally induced charge separation within the droplets is suggested be responsible for the generation of primary charged droplets inside the inlet capillary.…”
mentioning
confidence: 99%
“…Briefly, in inlet ionization (Movie S1, supporting information), an inlet tube connects atmospheric pressure with sub‐atmospheric pressure and, depending on the matrix and inlet geometry used, optimizes at different inlet temperatures, similar to different voltages used in ESI and laser fluence in MALDI. An illustration is shown in Figure for several matrices used in MS (Scheme ) in which a few tenths of a μL of a co‐crystallized sample of the respective matrix solution is mixed with a 1 ppm solution of gramicidin S on a microscope cover slip slide, allowed to dry, and a small particle is introduced into the inlet.…”
Section: Brief Classifications and How The New Ionization Methods Arementioning
confidence: 99%
“…Using a temperature range from 70 to 400 °C on an Orbitrap Q‐Exactive Focus mass spectrometer produces for 3‐NBN matrix exceptionally high analyte ion abundance without the need for high voltages or a laser , while other matrices, especially typical MALDI matrices, produce less abundant analyte ions, multiply and singly charged, and only at high temperatures. The temperature can be applied directly or indirectly to the tube, typically used as an ESI inlet . Charge separation occurs after the matrix is introduced to sub‐atmospheric pressure.…”
Section: Brief Classifications and How The New Ionization Methods Arementioning
confidence: 99%
“…It is difficult to attribute results to the ion suppression issue described in MALDI and ESI [55,56] considering the ICP-MS results, showing that MAI and MALDI both overrepresented the concentration of Eu-PEG products. Additionally, initial results from ionizing thermometer molecules using MAI indicate that MAI is harsher for small molecules than ESI [57] and the fact that typical capillary and extraction voltages were applied making fragmentation of the Eu-PEG product during ionization unlikely because of the inherently softer ionization afforded by ESI relative to MALDI [58].…”
Section: Ionizationmentioning
confidence: 99%