2010
DOI: 10.1063/1.3488098
|View full text |Cite
|
Sign up to set email alerts
|

Surface pump-probe femtosecond-laser mass spectrometry: Time-, mass-, and velocity-resolved detection of surface reaction dynamics

Abstract: A detailed account of the experimental methodology of surface pump-probe femtosecond-laser mass spectrometry is presented. This recently introduced technique enables the direct time-resolved investigation of surface reaction dynamics by monitoring the mass and the relative velocity of intermediates and products of a photoinduced surface reaction via multiphoton ionization. As a model system, the photodissociation dynamics of methyl iodide adsorbed at submonolayer coverage on magnesia ultrathin films is investi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
1
1

Relationship

4
4

Authors

Journals

citations
Cited by 11 publications
(23 citation statements)
references
References 61 publications
(53 reference statements)
1
22
0
Order By: Relevance
“…The CD 3 + transient signal consists of a peak structure with a maximum at 50 fs. The interpretation of this transient is based on earlier experiments with methyl iodide on an insulating magnesia surface and on the power dependences of the pump and the probe laser, which support a single-photon excitation followed by a two-photon ionization [18,3839]. …”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…The CD 3 + transient signal consists of a peak structure with a maximum at 50 fs. The interpretation of this transient is based on earlier experiments with methyl iodide on an insulating magnesia surface and on the power dependences of the pump and the probe laser, which support a single-photon excitation followed by a two-photon ionization [18,3839]. …”
Section: Resultsmentioning
confidence: 94%
“…Mass measurements were carried out on a homebuilt time-of-flight mass spectrometer [18,39]. The grounded Au/Mo(100) substrate served as the repeller electrode of a Wiley–McLaren-type acceleration lens arrangement [41].…”
Section: Methodsmentioning
confidence: 99%
“…One year later, the group published a paper again concerning MgO and CH 3 I/CD 3 I system, but with stronger focus on the experimental procedures (Vaida & Bernhardt, ). The surface photoexcitation, the resonant multiphoton ionization detection scheme and the time‐resolved pump‐probe measurements were explained in greater detail, as were the photodissociation dynamics.…”
Section: Photodissociationmentioning
confidence: 99%
“…Nevertheless, the direct time-and mass-resolved detection of the transition state and the product formation dynamics of a bimolecular surface reaction as proposed by Polanyi and Zewail has been realized only very recently employing the new approach of surface pump-probe femtosecond-laser mass spectrometry. 6,7 This technique relies on the combination of time-of-flight mass spectrometry with non-resonant or resonance enhanced multi-photon ionization (REMPI) detection and fast surface preparation by a pulsed molecular beam. 7 Ultrathin oxide films serve as versatile substrates that interact only weakly with adsorbed molecules.…”
Section: Introductionmentioning
confidence: 99%