2014
DOI: 10.4236/jbnb.2014.53018
|View full text |Cite
|
Sign up to set email alerts
|

Surface Plasmon Resonance for C-Reactive Protein Detection in Human Plasma

Abstract: In this work, we describe an approach of detecting biomarkers by Surface Plasmon Resonance imaging (SPRi) technique in real samples. Two C-Reactive Protein (CRP)-antibody immobilization methods were used: The first method was based on direct physisorption of CRP-antibody onto gold surface; the second one was based on oriented CRP-antibody with protein G intermediate layer.The two developed immunosensors were tested against CRP antigen in phosphate buffer saline solution with the SPRi technique. The response of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 13 publications
(13 reference statements)
0
9
0
Order By: Relevance
“…Mainly, physisorption does not depend on multistep and long experimental procedures (Marrakchi et al, ). In addition, physisorbed phages have been described to promote bacteria‐specific capture, infection, and lysis, when monitored by SPR (Chammem et al, ; Mejri et al, ). Physisorption was used in this work for transducer functionalization based on its simplicity.…”
Section: Resultsmentioning
confidence: 99%
“…Mainly, physisorption does not depend on multistep and long experimental procedures (Marrakchi et al, ). In addition, physisorbed phages have been described to promote bacteria‐specific capture, infection, and lysis, when monitored by SPR (Chammem et al, ; Mejri et al, ). Physisorption was used in this work for transducer functionalization based on its simplicity.…”
Section: Resultsmentioning
confidence: 99%
“…The paper-based discs are disposable while the PCB substrate can be reused. In comparison to other rapid, sensitive and portable label-free biosensors for protein quantification that have recently been reported in the literature [16][17][18][19][20][21][22][23][24][25][26][27][28], the presented method has improved cost-effectiveness, simplification and ease of use. Thus, although an increased upper limit of detection for our presented methodology is suspected, further research should be carried out to determine whether it may be applicable for the measurement of protein biomarkers of a broadened range of concentrations.…”
Section: Analysis and Comparison With Elisa And Recently Developed Mementioning
confidence: 97%
“…Mainly, physisorption does not depend on multistep, long experimental procedures and is easily reversed [19]. In addition, physisorbed phages have been described to promote bacteria-specific capture, infection, and lysis, when monitored by SPR [20,21]. This work was carried using physisorption functionalization based on its simplicity.…”
Section: Physisorption Of Polyclonal Antibody On Interdigitated Gold mentioning
confidence: 99%