2007
DOI: 10.1016/j.susc.2007.04.050
|View full text |Cite
|
Sign up to set email alerts
|

Surface investigation of Si(100), Cu, Cu on Si(100), and Au on Cu with positron annihilation induced Auger-electron spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 21 publications
0
14
0
Order By: Relevance
“…Figure 5 shows the PAES and EAES spectra for a clean Si(100) surface and for Si(100) covered with Cu. 36 The Si L2,3VV-Auger peak of pure Si can be clearly seen in the PAES and EAES results. For the Cu-covered sample, the Cu M2,3VV-Auger transition peak appears in addition to the Si peak.…”
Section: Application Of Positron Beams 5·1 Positron-annihilation-indumentioning
confidence: 87%
“…Figure 5 shows the PAES and EAES spectra for a clean Si(100) surface and for Si(100) covered with Cu. 36 The Si L2,3VV-Auger peak of pure Si can be clearly seen in the PAES and EAES results. For the Cu-covered sample, the Cu M2,3VV-Auger transition peak appears in addition to the Si peak.…”
Section: Application Of Positron Beams 5·1 Positron-annihilation-indumentioning
confidence: 87%
“…Although the intensity of the 20 eV-beam has also been reduced to 2 Â 10 6 e + /s at the sample site, the preconditions for the PAES apparatus have been improved: using the primary positron beam, only a fraction of the emitted electrons had been detected due to the solid angle of only 8 Â 10 À3 sr and the small acceptance area of the actual electron energy analyzer (CLAM 2). Due to the higher brightness of the remoderated beam, more electrons can be analyzed and less electron background is produced at the magnetic field termination [6].…”
Section: Methodsmentioning
confidence: 99%
“…sample chamber, where they are nonadiabatically extracted and then focused onto the sample by electric lenses [6,7]. The sample can be biased and was set to À7 V in all presented measurements.…”
Section: Methodsmentioning
confidence: 99%
“…The current set up of NEPOMUC produces 9 · 10 8 primary positrons per second [4]. That lead to a reduction of the typical measurement time for a PAES spectrum to 10-12h [5].…”
Section: Paes Principlementioning
confidence: 99%
“…• a high solid angle is covered and reduces the measurement time compared to the previous set up [5] considerably. Table 1 The first measurements (Fig.…”
Section: Improved Set Upmentioning
confidence: 99%