2005 IEEE Pulsed Power Conference 2005
DOI: 10.1109/ppc.2005.300451
|View full text |Cite
|
Sign up to set email alerts
|

Surface Flashover Characteristics of Nano Particle Cast EPOXY Resin

Abstract: electrical insulation for multi-stress and high repetition rate (high frequency operation) compact and/or high Surface flashover across solid insulators in vacuum voltage/power electrical systems [4].has found applications in the area of space power systems. One scenario where surface flashover in vacuum can be a Insulating materials play a significant role in the problem in space power systems is a spacecraft operating design and performance of high voltage power systems.in geosynchronous orbit (GEO) or low e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 6 publications
(6 reference statements)
0
3
0
Order By: Relevance
“…On top of that, it is a challenge to produce a similar set of samples with the same finish all over the surface of the sample. For these reasons, an alternative flashover system is constructed in a typical surface breakdown arrangement as used by various authors [181][182][183] in which the breakdown is likely to occur along the sample surface and in between the triple junctions of electrode-epoxy-air as pictured in Figure 7-2. The tips of the electrodes are shaped like a finger with sharp edges as to generate corona effect in order to make sure that the flashover does occur at the tip of the electrodes.…”
Section: Flashover System Designmentioning
confidence: 99%
“…On top of that, it is a challenge to produce a similar set of samples with the same finish all over the surface of the sample. For these reasons, an alternative flashover system is constructed in a typical surface breakdown arrangement as used by various authors [181][182][183] in which the breakdown is likely to occur along the sample surface and in between the triple junctions of electrode-epoxy-air as pictured in Figure 7-2. The tips of the electrodes are shaped like a finger with sharp edges as to generate corona effect in order to make sure that the flashover does occur at the tip of the electrodes.…”
Section: Flashover System Designmentioning
confidence: 99%
“…The electrode system is constructed in a typical surface breakdown arrangement as used by various authors [10][11][12] in which the breakdown is likely to occur along the surface between the triple junctions of electrode-sample-gas. This test apparatus is designed to study the surface flashover strength of fluorinated epoxy samples of different fluorination times inside a controlled environment.…”
Section: Flashover In Nitrogen Gas Testmentioning
confidence: 99%
“…Illumination of electrode gaps with UV-rays aids easy ionization in gaps. Random emission of a small number of electrons at the cathode results in positive charging of the dielectric surface, thus initiating surface flashover across the dielectric [9].…”
mentioning